<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.radicaltechmart.com/blogs/tag/humidity-data-logger/feed" rel="self" type="application/rss+xml"/><title>Radical TechMart - Blog #Humidity Data Logger</title><description>Radical TechMart - Blog #Humidity Data Logger</description><link>https://www.radicaltechmart.com/blogs/tag/humidity-data-logger</link><lastBuildDate>Mon, 01 Jun 2026 05:58:43 +0530</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Rotronic Data Logger Selection Guide: Choose the Right model for Humidity, Temperature, Pressure & Dew Point Monitoring]]></title><link>https://www.radicaltechmart.com/blogs/post/rotronic-data-logger-selection-guide</link><description><![CDATA[<img align="left" hspace="5" src="https://www.radicaltechmart.com/blog-rotronic-DataLogger1.png"/>Compare Rotronic HL-1D, BL-1D, TL-1D and HL-20D data loggers for logistics, pharma, storage, museums and industrial monitoring. Choose the right Rotronic data logger for your application.]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_-Po5_67ES0yB2D0lrnIG_g" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_L5RIeVvXQXGWug3knqssnQ" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_sfTSJXMHRDOeo6KqRdc6iA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_S1RvT0fpTmalSxP0Z5D0OA" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;">Rotronic Data Loggers for Humidity, Temperature, Pressure &amp; Dew Point</span></h2></div>
<div data-element-id="elm_RB8MKStTRWmDvcLj4GtJ_g" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div style="color:inherit;"><div style="color:inherit;"><p style="text-align:justify;"><a href="https://www.radicaltechmart.com/collections/rotronic-co2/138206000009256489" title="Buy Rotronic Data Loggers here" rel="">Buy Rotronic Data Loggers here</a></p><p style="text-align:justify;">In temperature and humidity monitoring, the problem usually starts after the damage is already done. A pharma shipment crosses the allowed temperature limit. A storage room becomes too humid. A museum display area silently develops moisture issues. A warehouse team realizes too late that nobody has recorded the actual environmental condition.</p><p style="text-align:justify;">This is where a <strong>Rotronic data logger</strong> becomes useful. It records environmental parameters such as humidity, temperature, pressure and dew point so that quality teams, logistics teams and maintenance teams can check what actually happened over time.</p><p style="text-align:justify;">For buyers, the main question is not simply “Which data logger is available?” The better question is:</p><p style="text-align:justify;"><strong>Which Rotronic data logger matches my monitoring requirements — humidity, temperature, pressure, dew point, storage capacity, accuracy and application?</strong></p><p style="text-align:justify;">Radical TechMart offers these Rotronic data logger models:</p><ol><li style="text-align:justify;"><strong>Rotronic HL-1D Humidity and Temperature Data Logger</strong></li><li style="text-align:justify;"><strong>Rotronic BL-1D Ambient Pressure and Dew Point Humidity Data Logger</strong></li><li style="text-align:justify;"><strong>Rotronic TL-1D Compact Data Logger</strong></li><li style="text-align:justify;"><strong>Rotronic HL-20D Humidity and Temperature Data Logger</strong></li></ol><p style="text-align:justify;">Let’s understand where each model fits.</p><p style="text-align:justify;"><br></p><hr style="text-align:justify;"/><h2 style="text-align:justify;">What is a Rotronic Data Logger?</h2><p style="text-align:justify;">A <strong>Rotronic data logger</strong> is a compact monitoring device used to record environmental data over time. Depending on the model, it can record:</p><ul><li style="text-align:justify;"> Relative humidity </li><li style="text-align:justify;"> Temperature </li><li style="text-align:justify;"> Pressure </li><li style="text-align:justify;"> Dew point </li></ul><p style="text-align:justify;">The recorded data helps users verify storage conditions, transportation conditions, building environments, pharma compliance, and process monitoring requirements.</p><p style="text-align:justify;">The HL-1D / BL-1D / TL-1D catalogue mentions that these models are suitable for <strong>logistics, pharmaceuticals and pharmacies</strong>, and support logging intervals from <strong>30 seconds to 24 hours</strong> with <strong>32,000 lines storage capacity</strong>. </p><p style="text-align:justify;">The HL-20D catalogue positions the model for <strong>logistics, production and storage, buildings and museums</strong>, with humidity and temperature recording and a memory capacity of <strong>20,000 value pairs</strong>. </p><p style="text-align:justify;"><br></p><hr style="text-align:justify;"/><h2 style="text-align:justify;">Why Correct Data Logger Selection Matters</h2><p style="text-align:justify;">Many buyers select a data logger only by price or brand name. That can create problems later.</p><p style="text-align:justify;">For example:</p><ul><li style="text-align:justify;"> A temperature-only logger will not help if humidity is the actual problem. </li><li style="text-align:justify;"> A humidity logger without pressure monitoring may not suit applications where ambient pressure is important. </li><li style="text-align:justify;"> A logger with lower accuracy may not be suitable for sensitive storage. </li><li style="text-align:justify;"> A logger without enough memory may not be suitable for long monitoring periods. </li><li style="text-align:justify;"> A model selected without checking software compatibility may create reporting issues. </li></ul><p style="text-align:justify;">In actual plant, warehouse, pharma and logistics conditions, the right data logger should be selected based on:</p><ul><li style="text-align:justify;"> Parameter to be measured </li><li style="text-align:justify;"> Accuracy requirement </li><li style="text-align:justify;"> Storage capacity </li><li style="text-align:justify;"> Logging interval </li><li style="text-align:justify;"> Software/reporting requirement </li><li style="text-align:justify;"> Environmental protection </li><li style="text-align:justify;"> Application type </li><li style="text-align:justify;"> Calibration and certificate requirement</li></ul><div style="text-align:justify;"><br></div><hr style="text-align:justify;"/><h2 style="text-align:justify;">1. Rotronic HL-1D Humidity and Temperature Data Logger</h2><p style="text-align:justify;">The <strong><a href="https://www.radicaltechmart.com/products/rotronic-hl-1d-humidity-temperature-data-logger/138206000008732159" title="Rotronic HL-1D " rel="">Rotronic HL-1D</a></strong> is suitable when the buyer needs to monitor both <strong>relative humidity and temperature</strong> in a compact logger format. It is a practical choice for storage, pharma, logistics, and controlled indoor spaces where both temperature and humidity affect product quality.</p><p></p><div style="text-align:justify;"><strong style="color:inherit;">Best for:</strong></div><div style="text-align:justify;"><span style="color:inherit;">Humidity and temperature monitoring in logistics, pharma storage, pharmacies, warehouses and controlled rooms.</span></div><p></p><p></p><div style="text-align:justify;"><strong style="color:inherit;">Why this model makes sense:</strong></div><div style="text-align:justify;"><span style="color:inherit;">The HL-1D records humidity and temperature together, making it useful when moisture and temperature variation both matter. This is important in pharma, packaging, storage rooms and transport applications where only temperature data may not be enough.</span></div><p></p><p style="text-align:justify;"><strong>Technical points to note:</strong></p><ul><li style="text-align:justify;"> Measures humidity and temperature </li><li style="text-align:justify;"> Humidity range: 0 to 100 %rh, non-condensing </li><li style="text-align:justify;"> Temperature range: -30 to 70 °C </li><li style="text-align:justify;"> Storage capacity: 32,000 lines </li><li style="text-align:justify;"> Logging interval: 30 seconds to 24 hours </li><li style="text-align:justify;"> LCD display with 2 lines </li><li style="text-align:justify;"> USB-Mini communication </li><li style="text-align:justify;"> IP67 protection class </li><li style="text-align:justify;"> Battery: 1 × CR2 </li><li style="text-align:justify;"> Certified to EN 12830 </li><li style="text-align:justify;"> FDA 21 CFR Part 11 / GAMP 5-compliant HW4 software support mentioned in the catalogue </li></ul><p style="text-align:justify;"><strong>Where it is commonly used:</strong></p><ul><li style="text-align:justify;"> Pharma storage </li><li style="text-align:justify;"> Medicine shops and pharmacies </li><li style="text-align:justify;"> Cold-chain logistics </li><li style="text-align:justify;"> Warehouses </li><li style="text-align:justify;"> Packaging areas </li><li style="text-align:justify;"> Controlled indoor storage rooms </li></ul><p></p><div style="text-align:justify;"><strong style="color:inherit;">Selection caution:</strong></div><div style="text-align:justify;"><span style="color:inherit;">Choose HL-1D when humidity and temperature both matter. If you need pressure and dew point also, BL-1D will be the more suitable option.</span></div><div style="text-align:justify;"><span style="color:inherit;"><br></span></div><p></p><hr style="text-align:justify;"/><h2 style="text-align:justify;">2. Rotronic BL-1D Ambient Pressure and Dew Point Humidity Data Logger</h2><p style="text-align:justify;">The <strong><a href="https://www.radicaltechmart.com/products/rotronic-bl-1d-ambient-pressure-dew-point-logger/138206000008732235" title="Rotronic BL-1D" rel="">Rotronic BL-1D</a></strong> is the right choice when the application requires more than basic humidity and temperature logging. It records <strong>process pressure, dew point, humidity and temperature</strong>, making it useful for applications where environmental condition analysis is more detailed.</p><p></p><div style="text-align:justify;"><strong style="color:inherit;">Best for:</strong></div><div style="text-align:justify;"><span style="color:inherit;">Applications where humidity, temperature, pressure and dew point need to be monitored together.</span></div><p></p><p></p><div style="text-align:justify;"><strong style="color:inherit;">Why this model makes sense:</strong></div><div style="text-align:justify;"><span style="color:inherit;">In some applications, humidity and temperature alone do not give the complete picture. Dew point helps users understand condensation risk, while pressure monitoring can be important for controlled environments, labs, storage areas and sensitive process locations.</span></div><p></p><p style="text-align:justify;"><strong>Technical points to note:</strong></p><ul><li style="text-align:justify;"> Measures pressure, dew point, humidity and temperature </li><li style="text-align:justify;"> Pressure measurement method: Bosch BMP280 </li><li style="text-align:justify;"> Pressure range: 300 to 1100 hPa </li><li style="text-align:justify;"> Pressure accuracy: ±3 hPa at 0 to 65 °C / ±5 hPa others </li><li style="text-align:justify;"> Dew point calculated from humidity and temperature </li><li style="text-align:justify;"> Humidity range: 0 to 100 % RH, non-condensing </li><li style="text-align:justify;"> Temperature range: -30 to 70 °C </li><li style="text-align:justify;"> Storage capacity: 32,000 lines </li><li style="text-align:justify;"> USB-Mini communication </li><li style="text-align:justify;"> IP67 protection class </li><li style="text-align:justify;"> HW4 software support mentioned in the catalogue </li></ul><p style="text-align:justify;"><strong>Where it is commonly used:</strong></p><ul><li style="text-align:justify;"> Pharma monitoring </li><li style="text-align:justify;"> Laboratory environments </li><li style="text-align:justify;"> Storage areas where condensation risk matters </li><li style="text-align:justify;"> Ambient pressure monitoring </li><li style="text-align:justify;"> Controlled rooms </li><li style="text-align:justify;"> Quality monitoring applications </li></ul><p></p><div style="text-align:justify;"><strong style="color:inherit;">Selection caution:</strong></div><div style="text-align:justify;"><span style="color:inherit;">Select BL-1D when pressure and dew point are required. If only temperature is needed, TL-1D may be more cost-effective. If only humidity and temperature are needed, HL-1D or HL-20D may be enough.</span></div><div style="text-align:justify;"><span style="color:inherit;"><br></span></div><p></p><hr style="text-align:justify;"/><h2 style="text-align:justify;">3. Rotronic TL-1D Compact Data Logger</h2><p style="text-align:justify;">The <strong><a href="https://www.radicaltechmart.com/products/rotronic-tl-1d-compact-data-logger/138206000008732309" title="Rotronic TL-1D" rel="">Rotronic TL-1D</a></strong> is suitable when the main requirement is <strong>temperature logging</strong> in a compact device. It is a good option when humidity or pressure measurement is not required and the buyer wants simple temperature monitoring with good storage capacity.</p><p></p><div style="text-align:justify;"><strong style="color:inherit;">Best for:</strong></div><div style="text-align:justify;"><span style="color:inherit;">Temperature-only monitoring in logistics, storage, pharma, pharmacies and general temperature tracking applications.</span></div><p></p><p></p><div style="text-align:justify;"><strong style="color:inherit;">Why this model makes sense:</strong></div><div style="text-align:justify;"><span style="color:inherit;">Not every application requires humidity measurement. In many cases, the main requirement is to prove that the temperature stayed within the accepted range. TL-1D fits this requirement because it is focused on temperature and has high storage capacity.</span></div><p></p><p style="text-align:justify;"><strong>Technical points to note:</strong></p><ul><li style="text-align:justify;"> Temperature data logger </li><li style="text-align:justify;"> Temperature range: -30 to 70 °C </li><li style="text-align:justify;"> Temperature measurement method: NTC </li><li style="text-align:justify;"> Temperature accuracy: ±0.3 K at -30 to 70 °C / ±0.5 K others </li><li style="text-align:justify;"> Resolution: 0.1 °C </li><li style="text-align:justify;"> Storage capacity: 32,000 lines </li><li style="text-align:justify;"> Logging interval: 30 seconds to 24 hours </li><li style="text-align:justify;"> LCD display with 2 lines </li><li style="text-align:justify;"> USB-Mini communication </li><li style="text-align:justify;"> IP67 protection class </li><li style="text-align:justify;"> Battery life mentioned as 1 year at 1 hour logging interval and room temperature </li></ul><p style="text-align:justify;"><strong>Where it is commonly used:</strong></p><ul><li style="text-align:justify;"> Cold storage temperature checks </li><li style="text-align:justify;"> Pharma temperature records </li><li style="text-align:justify;"> Transport temperature monitoring </li><li style="text-align:justify;"> Pharmacy storage </li><li style="text-align:justify;"> Warehouse temperature logging </li><li style="text-align:justify;"> General temperature audits </li></ul><p></p><div style="text-align:justify;"><strong style="color:inherit;">Selection caution:</strong></div><div style="text-align:justify;"><span style="color:inherit;">Do not select TL-1D if humidity data is required. For humidity and temperature, choose HL-1D or HL-20D.</span></div><div style="text-align:justify;"><span style="color:inherit;"><br></span></div><p></p><hr style="text-align:justify;"/><h2 style="text-align:justify;">4. Rotronic HL-20D Humidity and Temperature Data Logger</h2><p style="text-align:justify;">The <strong><a href="https://www.radicaltechmart.com/products/rotronic-hl-20d-humidity-temperature-data-logger/138206000008732375" title="Rotronic HL-20D" rel="">Rotronic HL-20D</a></strong> is a higher-accuracy humidity and temperature data logger suitable for users who need strong measurement performance and long-term stability.</p><p></p><div style="text-align:justify;"><strong style="color:inherit;">Best for:</strong></div><div style="text-align:justify;"><span style="color:inherit;">Applications where better humidity accuracy and stable long-term monitoring are important.</span></div><p></p><p></p><div style="text-align:justify;"><strong style="color:inherit;">Why this model makes sense:</strong></div><div style="text-align:justify;"><span style="color:inherit;">The HL-20D catalogue highlights humidity accuracy up to </span><strong style="color:inherit;">±0.8% RH in the 10 to 60% RH range</strong><span style="color:inherit;"> and temperature accuracy of </span><strong style="color:inherit;">±0.3 °C at 23 °C</strong><span style="color:inherit;">. This makes it suitable where humidity and temperature data need to be recorded with better confidence.</span></div><p></p><p style="text-align:justify;"><strong>Technical points to note:</strong></p><ul><li style="text-align:justify;"> Humidity and temperature data logger with internal sensors </li><li style="text-align:justify;"> Humidity measurement method: ROTRONIC HYGROMER® IN-1 </li><li style="text-align:justify;"> Humidity range: 0 to 100 %rh, non-condensing </li><li style="text-align:justify;"> Temperature measurement method: PT100 RTD, IEC 751 Class A </li><li style="text-align:justify;"> Temperature range: 0 to 50 °C </li><li style="text-align:justify;"> Recording capacity: 20,000 value pairs </li><li style="text-align:justify;"> Recorded parameters: relative humidity and temperature </li><li style="text-align:justify;"> Logging interval: minimum 5 seconds up to 1 hour </li><li style="text-align:justify;"> Battery: 3 × AA alkaline </li><li style="text-align:justify;"> Display: LC display with alarm and low-battery indication </li><li style="text-align:justify;"> Dimensions: 130 × 72 × 32 mm </li><li style="text-align:justify;"> IP protection: IP40 </li><li style="text-align:justify;"> Order codes: HL-20D and HL-20D-SET1 with AC3006 service cable </li></ul><p style="text-align:justify;"><strong>Where it is commonly used:</strong></p><ul><li style="text-align:justify;"> Logistics </li><li style="text-align:justify;"> Production and storage </li><li style="text-align:justify;"> Buildings </li><li style="text-align:justify;"> Museums </li><li style="text-align:justify;"> Display and test applications </li><li style="text-align:justify;"> Humidity-sensitive storage areas </li></ul><p></p><div style="text-align:justify;"><strong style="color:inherit;">Selection caution:</strong></div><div style="text-align:justify;"><span style="color:inherit;">HL-20D has IP40 protection, so confirm the installation environment before using it in dusty, wet or harsh field conditions. For compact IP67 applications, the HL-1D / BL-1D / TL-1D series may be more suitable.</span></div><div style="text-align:justify;"><span style="color:inherit;"><br></span></div><p></p><hr style="text-align:justify;"/><h1 style="text-align:justify;">Quick Comparison Table</h1><div><table style="text-align:justify;"><thead><tr><th>Model</th><th>Measures</th><th>Best Use</th></tr></thead><tbody><tr><td><strong>Rotronic HL-1D</strong></td><td>Humidity + Temperature</td><td>Compact humidity and temperature monitoring</td></tr><tr><td><strong>Rotronic BL-1D</strong></td><td>Pressure + Dew Point + Humidity + Temperature</td><td>Detailed environmental monitoring</td></tr><tr><td><strong>Rotronic TL-1D</strong></td><td>Temperature</td><td>Temperature-only logging</td></tr><tr><td><strong>Rotronic HL-20D</strong></td><td>Humidity + Temperature</td><td>Higher-accuracy humidity and temperature monitoring</td></tr></tbody></table></div>
<hr style="text-align:justify;"/><h2 style="text-align:justify;">How to Choose the Right Rotronic Data Logger</h2><h3 style="text-align:justify;">Choose HL-1D if:</h3><p style="text-align:justify;">You need a compact humidity and temperature logger for pharma, logistics, pharmacies or storage.</p><h3 style="text-align:justify;">Choose BL-1D if:</h3><p style="text-align:justify;">You need humidity, temperature, ambient pressure and dew point in one logger.</p><h3 style="text-align:justify;">Choose TL-1D if:</h3><p style="text-align:justify;">You only need temperature logging and do not require humidity or pressure.</p><h3 style="text-align:justify;">Choose HL-20D if:</h3><p style="text-align:justify;">You need better humidity accuracy, long-term stability and a larger display-style humidity-temperature logger.</p><p style="text-align:justify;"><br></p><hr style="text-align:justify;"/><h2 style="text-align:justify;">Common Mistakes to Avoid Before Buying a Data Logger</h2><div><table style="text-align:justify;"><thead><tr><th>Do This</th><th>Not This</th></tr></thead><tbody><tr><td>Select based on measured parameter</td><td>Do not buy temperature-only logger if humidity is important</td></tr><tr><td>Check storage capacity</td><td>Do not ignore logging duration</td></tr><tr><td>Confirm accuracy requirement</td><td>Do not select only by price</td></tr><tr><td>Check IP rating</td><td>Do not use indoor models in harsh environments</td></tr><tr><td>Confirm software/reporting needs</td><td>Do not assume every logger gives compliance-ready reports</td></tr><tr><td>Check calibration/certificate requirement</td><td>Do not wait until audit time</td></tr><tr><td>Confirm operating range</td><td>Do not use outside specified conditions</td></tr></tbody></table></div>
<hr style="text-align:justify;"/><h2 style="text-align:justify;">Quick Selection Checklist</h2><p style="text-align:justify;">Before purchasing a Rotronic data logger, confirm:</p><ol><li style="text-align:justify;"> Do you need temperature only, or humidity also? </li><li style="text-align:justify;"> Is dew point monitoring required? </li><li style="text-align:justify;"> Is ambient pressure monitoring required? </li><li style="text-align:justify;"> What is the required logging interval? </li><li style="text-align:justify;"> How many days/months of data need to be stored? </li><li style="text-align:justify;"> What accuracy is required for your application? </li><li style="text-align:justify;"> Will the logger be used indoors, outdoors, in transport or in storage? </li><li style="text-align:justify;"> Is IP67 protection required? </li><li style="text-align:justify;"> Is FDA/GMP software compliance important? </li><li style="text-align:justify;"> Do you need a calibration certificate or traceable documentation?</li></ol><div style="text-align:justify;"><br></div><hr style="text-align:justify;"/><h2 style="text-align:justify;">Why Buy Rotronic Data Loggers from Radical TechMart?</h2><p style="text-align:justify;">At Radical TechMart, the focus is not only to supply a data logger, but to help customers select the correct model for their monitoring requirement.</p><p style="text-align:justify;">Whether you need a <strong>Rotronic humidity data logger</strong>, <strong>temperature data logger</strong>, <strong>dew point logger</strong>, or <strong>pressure and humidity data logger</strong>, Radical TechMart can help you compare models based on application, parameter, accuracy, storage capacity and availability.</p><p style="text-align:justify;">These products are suitable for:</p><ul><li style="text-align:justify;"> Pharma companies </li><li style="text-align:justify;"> Logistics and cold-chain users </li><li style="text-align:justify;"> Warehouses </li><li style="text-align:justify;"> Pharmacies </li><li style="text-align:justify;"> Laboratories </li><li style="text-align:justify;"> Museums and buildings </li><li style="text-align:justify;"> Production and storage facilities </li><li style="text-align:justify;"> Quality monitoring teams </li></ul><div style="text-align:justify;"><br></div><hr style="text-align:justify;"/><h2 style="text-align:justify;">Final Thoughts</h2><p style="text-align:justify;">A data logger is not just a recording device. In many applications, it becomes proof of storage quality, shipment safety, audit compliance and process control.</p><p style="text-align:justify;">If your application only needs temperature monitoring, the <strong>Rotronic TL-1D</strong> may be suitable. If you need humidity and temperature together, choose <strong>HL-1D</strong> or <strong>HL-20D</strong> depending on accuracy and installation requirements. If your application also needs pressure and dew point, <strong>BL-1D</strong> is the better choice.</p><p style="text-align:justify;">In industrial and quality-sensitive applications, the right data logger should be selected by understanding the parameter, environment, logging duration, accuracy and reporting requirement — not only by price.</p><hr style="text-align:justify;"/><h1 style="text-align:justify;">FAQs</h1><h2 style="text-align:justify;"><span style="font-size:24px;">1. Which Rotronic data logger is best for humidity and temperature monitoring?</span></h2><p style="text-align:justify;">For humidity and temperature monitoring, <strong>Rotronic HL-1D</strong> and <strong>Rotronic HL-20D</strong> are suitable options. HL-1D is compact with IP67 protection, while HL-20D offers higher humidity accuracy and strong long-term stability.</p><h2 style="text-align:justify;"><span style="font-size:24px;">2. Which Rotronic data logger measures pressure and dew point?</span></h2><p style="text-align:justify;">The <strong>Rotronic BL-1D</strong> measures process pressure, dew point, humidity and temperature.</p><h2 style="text-align:justify;"><span style="font-size:24px;">3. Which Rotronic data logger is suitable for temperature-only monitoring?</span></h2><p style="text-align:justify;">The <strong>Rotronic TL-1D</strong> is suitable for temperature-only data logging applications.</p><h2 style="text-align:justify;"><span style="font-size:24px;">4. Are Rotronic data loggers suitable for pharma applications?</span></h2><p style="text-align:justify;">Yes, the HL-1D / BL-1D / TL-1D catalogue mentions applications such as pharmaceuticals and pharmacies, along with FDA 21 CFR Part 11 / GAMP 5-compliant HW4 software support. </p><h2 style="text-align:justify;"><span style="font-size:24px;">5. What is the storage capacity of Rotronic HL-1D, BL-1D and TL-1D?</span></h2><p style="text-align:justify;">The HL-1D / BL-1D / TL-1D series has a storage capacity of <strong>32,000 lines</strong>. </p><h2 style="text-align:justify;"><span style="font-size:24px;">6. What is the recording capacity of Rotronic HL-20D?</span></h2><p style="text-align:justify;">The Rotronic HL-20D has a recording capacity of <strong>20,000 value pairs</strong> for relative humidity and temperature. </p><h2 style="text-align:justify;"><span style="font-size:24px;">7. Which Rotronic data logger should I choose for logistics?</span></h2><p style="text-align:justify;">For logistics, HL-1D, TL-1D and HL-20D may be suitable depending on whether you need temperature only or humidity and temperature monitoring. BL-1D is better if pressure and dew point are also required.</p></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Fri, 15 May 2026 09:04:48 +0000</pubDate></item></channel></rss>