<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.radicaltechmart.com/blogs/tag/magnetic-flow-meter-for-conductive-liquids/feed" rel="self" type="application/rss+xml"/><title>Radical TechMart - Blog #magnetic flow meter for conductive liquids</title><description>Radical TechMart - Blog #magnetic flow meter for conductive liquids</description><link>https://www.radicaltechmart.com/blogs/tag/magnetic-flow-meter-for-conductive-liquids</link><lastBuildDate>Thu, 12 Nov 2026 18:51:59 +0530</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Electromagnetic Flow Meter: Selection, Installation and Common Mistakes]]></title><link>https://www.radicaltechmart.com/blogs/post/electromagnetic-flow-meter-installation-selection-guide</link><description><![CDATA[<img align="left" hspace="5" src="https://www.radicaltechmart.com/blog8-nov.jpg"/>Learn electromagnetic flow meter installation, selection and common mistakes. Understand conductivity, grounding, pipe filling, electrode materials and flow accuracy.]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_3yWde02cRGWeHMpIgYWeQA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_yGTVHpOMRD-_PbexNHOGFA" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_MqKe_dQPRFOu5L8HUK1_bw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_QOsW7DaSSTal46tPsMcYQg" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;">Electromagnetic Flow Meter Installation &amp; Selection Guide</span></h2></div>
<div data-element-id="elm_ejm-KRInR4W7TSl26qqbiw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-left " data-editor="true"><div style="color:inherit;"><p>A flow meter is installed on a water treatment pipeline. The pipe size matches, the transmitter display is working and the electrical connections appear correct.</p><p>But once the pump starts, the flow reading begins fluctuating. Sometimes the instrument shows a value even when the operator expects zero flow. At other times, the displayed flow rate does not match the plant's actual transfer quantity.</p><p>The maintenance team suspects a defective flow meter.</p><p>However, the actual problem may be the installation.</p><p>An electromagnetic flow meter can be correctly specified and still produce unreliable readings if the measuring tube is not completely filled, the grounding arrangement is incorrect or the process liquid does not meet the conductivity requirement.</p><p><strong>Electromagnetic flow meter installation is not simply about fitting an instrument between two pipeline flanges. The process liquid, pipe conditions and electrical installation all influence measurement performance.</strong></p><p>This guide explains how electromagnetic flow meters work, how to select the right instrument and which installation mistakes should be avoided in water treatment plants, chemical industries, wastewater systems and industrial process pipelines.</p><h2>What Is an Electromagnetic Flow Meter?</h2><p>An electromagnetic flow meter, also called a magnetic flow meter or magmeter, measures the volumetric flow rate of electrically conductive liquids.</p><p>Unlike mechanical flow meters that use a turbine or rotating element, an electromagnetic flow meter measures liquid movement through an induced electrical voltage.</p><p>The measuring tube contains no rotating flow measurement components.</p><p>This makes the technology useful for many industrial liquids, including water, wastewater and suitable conductive slurries.</p><p>A typical electromagnetic flow meter consists of:</p><ul><li><p><strong>Measuring tube:</strong> Provides the flow passage through the instrument.</p></li><li><p><strong>Magnetic coils:</strong> Generate the magnetic field required for measurement.</p></li><li><p><strong>Electrodes:</strong> Detect the voltage produced by the moving conductive liquid.</p></li><li><p><strong>Insulating lining:</strong> Electrically separates the measuring liquid from the metal measuring tube.</p></li><li><p><strong>Electronic transmitter:</strong> Processes the measured signal and provides flow indication or output to a control system.</p></li></ul><p>The important limitation is that the liquid must have sufficient electrical conductivity.</p><p>An electromagnetic flow meter is therefore not a universal solution for every liquid flowing through an industrial pipeline.</p><h2>How Does an Electromagnetic Flow Meter Work?</h2><p>Electromagnetic flow measurement is based on Faraday's law of electromagnetic induction.</p><p>When an electrically conductive liquid passes through a magnetic field, a voltage is generated across the liquid.</p><p>The flow meter's electrodes detect this voltage.</p><p>The induced voltage is proportional to the velocity of the liquid moving through the magnetic field.</p><p>The basic relationship is:</p><p><strong>Induced Voltage = Magnetic Field Strength × Electrode Spacing × Fluid Velocity</strong></p><p>Since the internal cross-sectional area of the measuring tube is known, the transmitter can calculate volumetric flow.</p><p><strong>Volumetric Flow Rate = Flow Velocity × Pipe Cross-Sectional Area</strong></p><p>In simple words, the faster the conductive liquid moves through the flow meter, the greater the induced measuring voltage.</p><p>The transmitter converts that measurement into a readable flow value.</p><p>Depending on the selected model, the information may be displayed locally or transmitted to a PLC, indicator, controller or SCADA system.</p><p>One practical advantage of this measuring principle is that changes in fluid pressure, temperature and viscosity have little direct effect on the measurement principle.</p><p>However, the instrument's physical pressure and temperature limits, liner compatibility and electrode suitability must still be respected.</p><h2>The First Selection Mistake: Ignoring Liquid Conductivity</h2><p>A purchase inquiry often begins with a simple requirement.</p><p>&quot;We need an electromagnetic flow meter for a 100 mm pipeline.&quot;</p><p>But pipe diameter alone does not determine whether the instrument is suitable.</p><p>The first question should be: <strong>What liquid is flowing through the pipeline?</strong></p><p>Electromagnetic flow meters require electrically conductive liquids because their measurement depends on the voltage generated by the moving fluid.</p><p>If the liquid conductivity is below the selected instrument's minimum requirement, the transmitter may not receive a usable measurement signal.</p><p>This becomes especially important when a process uses liquids with low conductivity.</p><p>An electromagnetic meter should not be selected for oils, hydrocarbons or other non-conductive liquids merely because the nominal pipeline size matches.</p><p>For suitable applications, the technology can be considered for:</p><ul><li><p>Raw water and treated water</p></li><li><p>Wastewater and industrial effluent</p></li><li><p>Conductive chemical solutions</p></li><li><p>Brine and salt solutions</p></li><li><p>Certain food and beverage liquids</p></li><li><p>Suitable slurries and process suspensions</p></li></ul><p>Before selecting the meter, confirm the liquid composition and minimum electrical conductivity under normal operating conditions.</p><h2>Electromagnetic Flow Meter Selection: Important Parameters</h2><p>The correct selection begins with the process requirement rather than only the flow meter price.</p><table><tbody><tr><th>Selection Parameter</th><th>What to Check</th><th>Why It Matters</th></tr><tr><td>Liquid type</td><td>Water, effluent, chemical or slurry</td><td>Determines measurement suitability</td></tr><tr><td>Conductivity</td><td>Minimum operating conductivity</td><td>Required for a usable measurement signal</td></tr><tr><td>Pipe diameter</td><td>Actual pipeline size</td><td>Determines physical fitment</td></tr><tr><td>Flow range</td><td>Minimum, normal and maximum flow</td><td>Helps select the appropriate measuring capacity</td></tr><tr><td>Liner material</td><td>Chemical and abrasion compatibility</td><td>Protects the measuring tube</td></tr><tr><td>Electrode material</td><td>Compatibility with the process liquid</td><td>Supports reliable voltage detection</td></tr><tr><td>Process temperature</td><td>Normal and maximum temperature</td><td>Must remain within material ratings</td></tr><tr><td>Process pressure</td><td>Operating and design pressure</td><td>Determines mechanical suitability</td></tr><tr><td>Output signal</td><td>Analog, pulse or digital as offered</td><td>Supports control system integration</td></tr><tr><td>Mounting position</td><td>Horizontal, vertical or other permitted arrangement</td><td>Helps maintain suitable measurement conditions</td></tr><tr><td>Grounding</td><td>Manufacturer-specified potential equalization</td><td>Reduces electrical measurement problems</td></tr><tr><td>Enclosure protection</td><td>Environmental rating and exposure</td><td>Helps protect the transmitter</td></tr></tbody></table><p>For chemical or abrasive applications, lining and electrode selection deserve particular attention.</p><p>A meter intended for cooling water may not need the same wetted materials as a meter used for an aggressive chemical solution.</p><h2>Why Lining and Electrode Materials Matter</h2><p>Inside the electromagnetic flow meter, the liner and electrodes are exposed to the process liquid.</p><p>The liner serves as an electrical insulator and also protects the measuring tube.</p><p>Depending on the product design, electromagnetic flow meter liners may use materials such as PTFE, PFA, polyurethane or hard rubber.</p><p>The correct material depends on the process conditions.</p><p>For example, a liquid containing abrasive particles may require different material considerations from a chemically aggressive solution.</p><p>The electrodes also need to be compatible with the liquid.</p><p>Electrode materials used in electromagnetic flow meter designs can include stainless steel, Hastelloy, tantalum and other suitable materials.</p><p>The choice should be based on the actual chemical composition and operating conditions.</p><p><strong>Selection caution:</strong> Do not assume that a PTFE liner or stainless steel electrode is suitable for every process.</p><p>The final lining and electrode materials should be confirmed against the specific liquid, concentration, temperature and manufacturer compatibility information.</p><h2>Electromagnetic Flow Meter Installation: Why a Full Pipe Matters</h2><p>One of the most important conditions for reliable electromagnetic flow measurement is that the measuring tube should remain completely filled with liquid.</p><p>Consider a pipeline carrying water from an overhead tank.</p><p>When the pump operates, the pipe may be full. But when the pump stops, part of the pipeline may drain because of the piping layout.</p><p>If the electromagnetic flow meter is installed in a section that becomes partially filled, the measurement can become inaccurate or unavailable.</p><p>This happens because the instrument calculates flow based on the measuring tube's defined cross-sectional area.</p><p>A partially filled pipe does not provide the same measurement conditions as a completely filled pipe.</p><p>Some electromagnetic flow meters include empty pipe detection to identify this problem.</p><p>However, empty pipe detection should not be treated as a replacement for correct installation.</p><p><strong>Practical installation advice:</strong> Select a pipeline location where the meter remains completely filled during the intended measurement conditions.</p><p>Avoid locations where air can accumulate, the pipe drains frequently or the measuring electrodes may become exposed.</p><p>Where the piping design allows, a suitable installation before an inverted siphon can help maintain a full measuring tube.</p><h2>Straight Pipe Length: Why Installation Location Matters</h2><p>An electromagnetic flow meter may be installed close to a pump, elbow, valve or reducer simply because that is where space is available.</p><p>But the nearest convenient flange location is not always the best measuring point.</p><p>Changes in pipeline geometry can affect flow conditions.</p><p>The required straight pipe lengths depend on the specific meter design and manufacturer instructions.</p><p>For planning purposes, the installation should be reviewed for:</p><ul><li><p>Upstream pipe bends and elbows</p></li><li><p>Control valves and partially open valves</p></li><li><p>Pumps and nearby discharge connections</p></li><li><p>Reducers and expanders</p></li><li><p>Available upstream straight pipe</p></li><li><p>Available downstream straight pipe</p></li><li><p>Flow direction and the expected operating range</p></li></ul><p>Do not assume that every electromagnetic flow meter requires exactly the same upstream and downstream distances.</p><p>Some designs may tolerate more demanding piping layouts than others.</p><p>Before fabrication, confirm the model-specific installation requirements.</p><p>The practical lesson is simple: <strong>the installation position should be finalized before purchasing the flow meter, not after the piping is completed.</strong></p><h2>Why Grounding Is Important in Electromagnetic Flow Meter Installation</h2><p>Electromagnetic flow meters measure relatively small electrical signals produced by the flowing liquid.</p><p>The electrodes and measurement electronics need a suitable electrical reference.</p><p>If the installation does not provide proper potential equalization between the liquid and the meter, measurement problems may occur.</p><p>Possible symptoms include unstable readings, electrical noise or inconsistent measurement behaviour.</p><p>The correct grounding arrangement depends on the meter design and the type of pipeline.</p><p>For example, a metallic pipeline and a plastic pipeline may require different installation arrangements.</p><p>Some electromagnetic flow meter designs use a reference electrode, while other installations may require grounding rings or suitable grounding accessories.</p><p>These requirements must be confirmed from the manufacturer's installation documentation.</p><p>Also distinguish protective electrical earthing from the process potential equalization required for the measurement circuit.</p><p>Both may be important, but they do not necessarily serve the same purpose.</p><p><strong>Practical advice:</strong> Never assume that connecting the transmitter housing to earth automatically completes every grounding requirement for accurate flow measurement.</p><h2>Horizontal or Vertical Installation: Which Is Better?</h2><p>Both horizontal and vertical installations may be possible, depending on the meter design and process conditions.</p><p>The important consideration is whether the pipe remains filled and whether air, gas or solids can affect the measurement.</p><p>For a horizontal installation, the manufacturer may specify an electrode orientation that reduces the possibility of air affecting the electrodes or settled solids accumulating around them.</p><p>For a vertical installation, an upward flowing liquid can be useful in applications where maintaining a full measurement tube is important.</p><p>However, the correct orientation depends on the selected meter and piping arrangement.</p><p>Before installation, check:</p><ol start="1"><li><p>Manufacturer-permitted mounting positions.</p></li><li><p>Required electrode orientation.</p></li><li><p>Direction of flow.</p></li><li><p>Possibility of air accumulation.</p></li><li><p>Possibility of solids settling.</p></li><li><p>Maintenance and display accessibility.</p></li></ol><p>Do not rotate the instrument arbitrarily just to make the local display easier to read.</p><h2>Integral vs Remote Electromagnetic Flow Meter</h2><p>Another selection decision is whether the transmitter should be mounted directly on the flow sensor or installed separately.</p><h3>Integral Type</h3><p>In an integral electromagnetic flow meter, the electronic transmitter is mounted together with the measuring sensor.</p><p>This arrangement is convenient where the pipeline is easily accessible and the installation environment is suitable for the electronics.</p><p><strong>Best for:</strong> Accessible industrial pipelines where local flow indication and compact installation are preferred.</p><p><strong>Why it makes sense:</strong> The sensor and electronics form a compact assembly, reducing the need for separate transmitter mounting.</p><p><strong>Selection caution:</strong> Verify ambient temperature, vibration, moisture exposure and display accessibility.</p><h3>Remote Type</h3><p>In a remote electromagnetic flow meter, the flow sensor remains in the pipeline while the transmitter is mounted at a separate location.</p><p>This can be useful when the sensor is installed in a pit, difficult-to-access pipeline or another location where the display and electronics would be inconvenient to maintain.</p><p><strong>Best for:</strong> Remote installations, difficult access areas and applications requiring a separate transmitter location.</p><p><strong>Why it makes sense:</strong> The display and transmitter can be positioned where the maintenance team can inspect or operate them more conveniently.</p><p><strong>Selection caution:</strong> Confirm the manufacturer-approved cable type, cable length, grounding and wiring requirements before ordering.</p><h2>Common Electromagnetic Flow Meter Installation Mistakes</h2><p>Even a properly selected electromagnetic flow meter can produce poor results when the installation conditions are ignored.</p><table><tbody><tr><th>Common Mistake</th><th>Possible Result</th><th>Better Approach</th></tr><tr><td>Installing in a partially filled pipeline</td><td>Incorrect or unavailable measurement</td><td>Maintain a full measuring tube</td></tr><tr><td>Ignoring conductivity</td><td>Weak or unusable signal</td><td>Verify minimum liquid conductivity</td></tr><tr><td>Incorrect grounding</td><td>Electrical noise or unstable readings</td><td>Follow manufacturer grounding instructions</td></tr><tr><td>Installing where air collects</td><td>Intermittent measurement problems</td><td>Choose a suitable piping location</td></tr><tr><td>Ignoring electrode orientation</td><td>Increased risk of air or deposits affecting measurement</td><td>Follow the sensor installation diagram</td></tr><tr><td>Selecting incompatible liner</td><td>Premature liner damage</td><td>Verify chemical and abrasion resistance</td></tr><tr><td>Using unsuitable electrodes</td><td>Corrosion or measurement problems</td><td>Match materials to the process</td></tr><tr><td>Ignoring actual flow range</td><td>Poor low flow performance or unsuitable sizing</td><td>Check minimum, normal and maximum flow</td></tr><tr><td>Installing without reviewing nearby fittings</td><td>Unfavourable flow conditions</td><td>Verify straight pipe requirements</td></tr><tr><td>Leaving PLC configuration until commissioning</td><td>Incorrect displayed engineering values</td><td>Confirm output and scaling requirements early</td></tr></tbody></table><h2>Electromagnetic Flow Meter Showing Wrong or Fluctuating Readings?</h2><p>Suppose a magnetic flow meter is displaying a fluctuating flow rate during normal pump operation.</p><p>Before concluding that the instrument is defective, separate the problem into process, installation and signal checks.</p><p><strong>Check the process first.</strong> Is the pipeline actually full? Is there entrained air? Has the liquid composition or conductivity changed?</p><p><strong>Check the installation.</strong> Are the electrodes correctly oriented? Is there a suitable grounding arrangement? Is the meter installed according to the manufacturer's requirements?</p><p><strong>Check the transmitter.</strong> Are there diagnostic warnings, empty pipe alarms or abnormal configuration settings?</p><p><strong>Check the control system.</strong> If the local transmitter display is correct but the PLC shows an incorrect value, inspect the output signal and PLC scaling.</p><p>A useful troubleshooting sequence is:</p><ol start="1"><li><p>Confirm the actual process flow condition.</p></li><li><p>Check the transmitter display and diagnostics.</p></li><li><p>Verify pipe filling.</p></li><li><p>Check grounding and wiring.</p></li><li><p>Confirm the configured measuring range.</p></li><li><p>Compare the local indication with the receiving control system.</p></li><li><p>Correct one problem at a time.</p></li><li><p>Verify operation across the normal flow range.</p></li></ol><p>This avoids unnecessary replacement and makes it easier to identify the actual cause.</p><h2>Where Electromagnetic Flow Meters Are Commonly Used</h2><p>Electromagnetic flow meters are particularly relevant where conductive liquids must be measured continuously.</p><p><strong>Water and wastewater treatment:</strong> Monitoring raw water, treated water, sewage and industrial effluent flow.</p><p><strong>Chemical processing:</strong> Measuring compatible conductive chemical solutions where liner and electrode selection are important.</p><p><strong>Food and beverage processing:</strong> Measuring suitable conductive liquids with an appropriately selected hygienic instrument.</p><p><strong>Pulp and paper industries:</strong> Monitoring conductive pulp mixtures or process suspensions with suitable sensor construction.</p><p><strong>Industrial utilities:</strong> Measuring cooling water, process water and other compatible liquid distribution systems.</p><p><strong>OEM and automation systems:</strong> Providing flow measurement signals to suitable controllers, PLCs and supervisory monitoring systems.</p><p>The common requirement across these applications is sufficient liquid conductivity and appropriate process compatibility.</p><div style="color:inherit;"><h2>Frequently Asked Questions</h2><div><div><h3>1. What is the correct installation position for an electromagnetic flow meter?</h3>Install the meter where its measuring tube remains completely filled. Horizontal and vertical arrangements may be possible, depending on the model. Follow the manufacturer's instructions for electrode orientation, flow direction and required straight pipe lengths.</div><div><h3>2. Why is grounding important in electromagnetic flow meters?</h3>Grounding and potential equalization help establish a suitable electrical reference for measurement. Incorrect grounding can contribute to unstable readings and electrical interference. The exact arrangement depends on the pipeline and instrument design.</div><div><h3>3. How much straight pipe is required for electromagnetic flow meter installation?</h3>Required straight pipe lengths vary by manufacturer and model. Verify the specified upstream and downstream distances, especially where pumps, valves, elbows or reducers are near the installation point.</div><div><h3>4. Can an electromagnetic flow meter measure wastewater?</h3>Yes, provided the wastewater has sufficient conductivity and the instrument's liner, electrodes and other materials are suitable. Electromagnetic flow measurement can also be used for certain conductive slurries and suspensions.</div><div><h3>5. Why does an electromagnetic flow meter show fluctuating readings?</h3>Possible causes include partially filled pipes, entrained air, insufficient conductivity, poor grounding, electrical interference or actual variations in the process flow. Review process conditions and instrument diagnostics before changing calibration.</div><div><h3>6. Can an electromagnetic flow meter measure oil?</h3>Conventional electromagnetic flow meters are generally unsuitable for non-conductive oils and hydrocarbons. The liquid must meet the selected instrument's minimum conductivity requirement.</div><div><h3>7. What is the difference between an integral and remote electromagnetic flow meter?</h3>An integral meter has its electronics mounted together with the flow sensor. A remote version places the transmitter separately, which may be preferable for difficult-to-access or environmentally demanding installations.</div><div><h3>8. Where can I find electromagnetic flow meters for industrial applications?</h3><p>You can explore the <a href="https://www.radicaltechmart.com/categories/electromagnetic-flow-meters/138206000019877011?utm_source=chatgpt.com">Electromagnetic Flow Meters category at Radical TechMart</a>. Confirm process compatibility, sizing, outputs and installation requirements before ordering.</p></div></div></div><h2>Specifications to Confirm Before Purchase</h2><p>Before ordering an electromagnetic flow meter for an industrial pipeline, confirm:</p><ul><li><p>Exact process liquid and conductivity</p></li><li><p>Pipe diameter and connection standard</p></li><li><p>Minimum, normal and maximum flow</p></li><li><p>Required measuring accuracy</p></li><li><p>Normal and maximum process temperature</p></li><li><p>Operating pressure</p></li><li><p>Liner material</p></li><li><p>Electrode material</p></li><li><p>Integral or remote transmitter requirement</p></li><li><p>Available power supply</p></li><li><p>Required output signal</p></li><li><p>Communication compatibility</p></li><li><p>Totalizing requirement</p></li><li><p>Grounding and reference electrode arrangement</p></li><li><p>Available straight pipe length</p></li><li><p>Environmental protection requirement</p></li><li><p>Calibration and documentation requirements</p></li></ul><p>Specifications vary by model and manufacturer. Confirm the final datasheet before selection.</p><h2>Why Choose Radical TechMart for Electromagnetic Flow Meters?</h2><p>An electromagnetic flow meter inquiry often begins with a pipe size.</p><p>But a complete technical selection requires considerably more information.</p><p>Two pipelines with the same diameter may carry completely different liquids. One may contain cooling water, while another carries a chemical solution or abrasive wastewater.</p><p>The correct lining, electrode material, flow range and installation arrangement may therefore be different.</p><p>At Radical TechMart, buyers can begin by exploring the <a href="https://www.radicaltechmart.com/categories/electromagnetic-flow-meters/138206000019877011">Electromagnetic Flow Meters category</a> and identifying the type of instrument required.</p><p>For maintenance engineers, OEMs, EPC contractors, system integrators and purchase teams, a clear technical inquiry helps avoid selection errors before installation.</p><p>Share the liquid, pipe size, flow range, temperature, pressure, output requirements and installation conditions when requesting product information.</p><h2>Final Thoughts</h2><p>An electromagnetic flow meter can provide an effective solution for measuring conductive liquid flow without rotating measuring elements in the pipeline.</p><p>But correct selection alone is not enough.</p><p>The measuring tube must operate under suitable filling conditions. The grounding arrangement must be appropriate. The electrode and liner materials must match the process. The selected meter must also support the actual flow range and control system requirements.</p><p>Before installing an electromagnetic flow meter, ask three questions:</p><p><strong>Is the liquid suitable for electromagnetic measurement?</strong></p><p><strong>Will the meter remain correctly filled and electrically referenced during operation?</strong></p><p><strong>Does the selected instrument match the process and automation requirements?</strong></p><p>When those questions are answered before installation, the chances of obtaining dependable flow measurement improve considerably.</p><p>In industrial applications, a properly installed flow meter is often more valuable than a sophisticated instrument installed in the wrong location.</p></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 10 Nov 2026 06:30:00 +0000</pubDate></item></channel></rss>