RDCL Corrosion Resistant Hydrostatic Level Transmitter RDCLWLPSF
The RDCL RDCLWLPSF Corrosion Resistant Hydrostatic Level Transmitter is an industrial submersible liquid level sensor designed for continuous level measurement in water tanks, wastewater treatment systems, chemical storage tanks, and other compatible liquid reservoirs.
It operates using hydrostatic pressure measurement technology to provide reliable and accurate liquid level monitoring. The transmitter features corrosion-resistant PP or PTFE construction, making it suitable for demanding industrial environments and applications involving compatible chemicals and liquids.
The RDCLWLPSF supports measuring ranges up to 200 meters, offers 0.5% full-scale accuracy, and features IP68 protection for continuous submersible operation.
Available with multiple output configurations, including 4 to 20 mA, RS485, and analog voltage signals, the RDCLWLPSF is suitable for industrial automation, PLC monitoring, wastewater management, chemical processing, and liquid level control applications.
Customize
Share :
A. Product Overview
The RDCLWLPSF Corrosion Resistant Hydrostatic Level Transmitter is designed to measure liquid levels by detecting the hydrostatic pressure generated by the liquid column above the submerged sensor probe.
The transmitter is particularly suitable for applications where conventional metallic level sensors may experience corrosion due to exposure to aggressive liquids or demanding industrial conditions.
The RDCLWLPSF features a corrosion-resistant housing available in polypropylene (PP) or polytetrafluoroethylene (PTFE).
These materials provide chemical resistance for suitable industrial liquids, including selected acidic and alkaline solutions, subject to chemical compatibility.
Important Technical Specifications
Parameter | Specification |
|---|---|
Product Name | Corrosion Resistant Hydrostatic Level Transmitter |
Brand | RDCL |
Model Number | RDCLWLPSF |
Measurement Principle | Hydrostatic Pressure Measurement |
Sensor Type | Submersible Liquid Level Transmitter |
Measuring Range | Configurable Range Up to 200 Meters |
Output Options | 4 to 20 mA, 0 to 5V, 0 to 10V, 0.5 to 4.5V, RS485 |
Measurement Accuracy | 0.5% Full Scale |
Power Supply Options | 8 to 30V DC, 5V DC or 24V DC |
Protection Rating | IP68 |
Housing Material | PP or PTFE |
Cable Material | PVC or PUR |
Note: Measuring range, output signal, operating voltage, material and cable configuration should be selected according to application requirements.
Available specifications represent product configuration options and do not necessarily apply simultaneously to a single unit.
B. Working Principle
The RDCLWLPSF Corrosion Resistant Hydrostatic Level Transmitter operates using the hydrostatic pressure measurement principle, where the pressure produced by a liquid column is proportional to its height and density.
When the sensor probe is submerged in a liquid, the liquid above the probe generates pressure on the pressure-sensitive element.
The sensor detects this pressure and converts it into an electrical signal that represents the liquid level.
How It Works
1. Sensor Submersion
The RDCLWLPSF sensor probe is submerged inside a liquid storage tank, reservoir, wastewater collection tank or other compatible vessel.
The sensor is positioned at a suitable measurement point, generally near the bottom of the tank.
2. Hydrostatic Pressure Detection
The liquid column above the sensor generates hydrostatic pressure.
As the liquid level increases, the pressure acting on the sensing element increases. When the liquid level decreases, the pressure reduces.
3. Pressure Signal Measurement
The internal pressure-sensitive element detects the applied hydrostatic pressure and converts it into an electrical measurement signal.
4. Electronic Signal Processing
The transmitter's electronic circuit processes the pressure measurement and determines the corresponding liquid level using the configured measuring range and liquid density.
5. Output Signal Conversion
The measured liquid level is converted into the selected electrical output.
Available configurations include 4 to 20 mA, analog voltage outputs and RS485 communication.
6. Continuous Level Monitoring
The output is transmitted through the sensor cable to a compatible PLC, digital level indicator, data acquisition system or industrial monitoring controller.
C. Why Is the RDCLWLPSF Corrosion Resistant Hydrostatic Level Transmitter Used?
The RDCLWLPSF is used for continuous liquid level monitoring in industrial environments where corrosion resistance, submersible installation and automation compatibility are important.
Key Benefits
1. Corrosion Resistant Construction
The transmitter is available with PP or PTFE housing materials, providing resistance to various industrial chemicals when the selected material is compatible with the process liquid.
2. Continuous Liquid Level Measurement
The RDCLWLPSF provides continuous level measurements rather than only detecting predetermined high-level or low-level switching points.
3. Industrial Measurement Accuracy
The transmitter is specified with 0.5% full-scale accuracy, supporting industrial liquid level monitoring and process control applications.
4. Multiple Output Signal Options
Available output configurations include 4 to 20 mA, 0 to 5V, 0 to 10V, 0.5 to 4.5V and RS485.
This allows the transmitter to be selected for different compatible monitoring and automation systems.
5. Wide Measuring Range Availability
The RDCLWLPSF supports configurable measuring ranges up to 200 meters, allowing selection for different tank depths, reservoirs and liquid level measurement requirements.
6. IP68 Submersible Protection
The IP68 protection rating supports submerged operation under the specified conditions, making it suitable for industrial tanks and liquid reservoirs.
7. No Mechanical Moving Parts
The hydrostatic pressure sensing principle does not require moving floats, reducing mechanical wear associated with float-based measurement systems.
Common Applications
Industrial chemical storage tanks
Acid and alkali storage tanks with compatible materials
Wastewater treatment plants
Sewage collection tanks
Effluent treatment plants
Chemical neutralization tanks
Environmental monitoring systems
Liquid storage and distribution facilities
Automated pump control systems
Industrial liquid level monitoring
Water reservoirs and storage facilities
Compatible oil storage tanks
Application Note: Chemical compatibility must be verified for the selected PP or PTFE material, cable and sealing components.
Hydrostatic measurement in pressurized or sealed tanks may require additional pressure compensation or a different instrument configuration.
D. Suitable Buyers
The RDCLWLPSF Corrosion Resistant Hydrostatic Level Transmitter is suitable for industrial customers, system integrators, chemical processing companies and equipment manufacturers requiring continuous liquid level monitoring.
Buyer Category | Typical Requirement |
|---|---|
Chemical Manufacturing Companies | Level measurement in compatible chemical storage tanks |
Effluent Treatment Plant Operators | Monitoring liquid levels in ETP collection and treatment tanks |
Sewage Treatment Plant Operators | Continuous level monitoring in sewage collection and treatment systems |
Water Treatment Companies | Measuring levels in water tanks and reservoirs |
Industrial Plant Operators | Continuous monitoring of industrial liquid storage |
Chemical Storage Facilities | Monitoring liquid levels in corrosive environments |
Electroplating Industries | Monitoring compatible plating and process solutions |
OEM Equipment Manufacturers | Integration into industrial liquid handling equipment |
Automation System Integrators | Connecting level measurements to PLC systems |
The RDCLWLPSF is particularly relevant for buyers searching for a corrosion resistant hydrostatic level transmitter, PTFE submersible level sensor, PP chemical tank level transmitter, 4 to 20 mA submersible level sensor, RS485 liquid level transmitter or IP68 industrial hydrostatic level sensor.
E. Frequently Asked Questions (FAQ)
1. What is the RDCL RDCLWLPSF Corrosion Resistant Hydrostatic Level Transmitter?
The RDCLWLPSF is an industrial submersible level transmitter designed for continuous liquid level measurement using hydrostatic pressure sensing technology.
2. How does the RDCLWLPSF Hydrostatic Level Transmitter work?
The RDCLWLPSF operates by measuring the hydrostatic pressure generated by the liquid column above its submerged sensor probe.
As the liquid level rises, hydrostatic pressure increases. The sensor detects this pressure and converts it into an electrical signal corresponding to the liquid level.
3. What is the measuring range of the RDCLWLPSF?
The RDCLWLPSF product series supports measuring range configurations up to 200 meters.
The appropriate measuring range should be selected according to the maximum liquid depth, liquid density and installation requirements.
4. What is the difference between a hydrostatic level transmitter and a float level sensor?
A hydrostatic level transmitter measures liquid level by detecting the pressure generated by the liquid column.
The RDCLWLPSF uses pressure-based measurement without requiring a mechanical float.
5. What materials are used in the RDCLWLPSF?
The RDCLWLPSF is available with polypropylene (PP) or polytetrafluoroethylene (PTFE) housing materials.
The appropriate material must be selected according to the liquid's chemical composition and operating conditions.
6. Can the RDCLWLPSF measure liquid levels in chemical storage tanks?
The RDCLWLPSF can be considered for chemical tank level monitoring when the selected housing, cable and sealing materials are compatible with the stored chemical.
The chemical concentration, operating temperature and tank pressure must be evaluated before installation.
7. Does the RDCLWLPSF support a 4 to 20 mA output?
Yes. The RDCLWLPSF is available with a 4 to 20 mA analog output configuration.
This output can be used for continuous liquid level measurement with compatible PLCs, industrial indicators and process monitoring systems.
8. Does the RDCLWLPSF support RS485 communication?
Yes. The RDCLWLPSF product series includes an RS485 communication option.
The exact communication protocol, wiring arrangement and register configuration should be confirmed for the selected model.
9. Can the RDCLWLPSF be connected to a PLC?
Yes. The RDCLWLPSF can be connected to a compatible PLC through its selected analog output or supported RS485 communication interface.
The PLC must have an appropriate input module and signal configuration.
10. What is the accuracy of the RDCLWLPSF Hydrostatic Level Transmitter?
The RDCLWLPSF is specified with a measurement accuracy of 0.5% of full scale.
Actual level measurement performance also depends on the selected range, liquid density, installation conditions and system configuration.