RDCL Magnetoresistive Float Level Transmitter RDCLFS1000
The RDCL RDCLFS1000 Magnetoresistive Float Level Transmitter is an industrial liquid level measurement instrument designed for accurate and continuous monitoring of liquid levels in storage tanks and process vessels.
It operates using magnetoresistive sensing technology to provide reliable liquid level measurements and features a standard 4 to 20 mA analog output for integration with industrial monitoring and control systems.
The RDCLFS1000 operates on a 24V DC power supply and supports a measuring range of 0.3 to 6 meters. It is designed to withstand operating temperatures from minus 20°C to 125°C and features IP65 protection for industrial environments.
The transmitter is suitable for various industrial applications, including water treatment, chemical processing, pharmaceutical manufacturing, and continuous liquid level monitoring in industrial storage and processing systems.
Customize
Share :
A. Product Overview
The RDCL RDCLFS1000 Magnetoresistive Float Level Transmitter continuously measures liquid levels using a magnetic float and magnetoresistive sensing technology. As the liquid rises or falls, the float moves along the probe. Internal sensing elements detect the changing magnetic field and convert the float position into a proportional electrical signal.
The float does not contact the internal electronics. A 4 to 20 mA output connects to compatible PLCs, indicators and monitoring systems.
Material choices include stainless steel 304, stainless steel 316, F4 and polypropylene for compatible water, chemical and storage applications.
Important Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Magnetoresistive Float Level Transmitter |
| Brand | RDCL |
| Model Number | RDCLFS1000 |
| Measurement Principle | Magnetoresistive Float Sensing |
| Measurement Type | Continuous Liquid Level Measurement |
| Measuring Range | 0.3 to 6 meters |
| Output Signal | 4 to 20 mA |
| Power Supply | 24V DC |
| Accuracy Options | 10 mm or 20 mm |
| Medium Density | 0.5 to 2 g/cm³ |
| Working Temperature | Minus 20°C to 125°C |
| Working Pressure | 1.0 MPa |
| Protection Class | IP65 |
| Connection Types | Flange, Thread, Clamp and other configurations |
| Material Options | Stainless Steel 304, Stainless Steel 316, F4, PP |
| Applications | Industrial Tanks, Water Treatment, Chemical Processing and Liquid Storage |
B. Working Principle
The RDCLFS1000 uses the magnetoresistive effect: sensing element resistance changes with the magnetic field of a permanent magnet inside the float. Electronics detect its movement and calculate liquid level.
Step-by-Step Working Process
Magnetic Float Movement: A buoyant float containing a permanent magnet moves vertically along the sensing probe as liquid rises or falls.
Magnetic Field Detection: The magnet's position changes relative to magnetoresistive sensing elements inside the probe.
Resistance Variation: The sensing elements respond to the changing magnetic field through variations in electrical resistance.
Signal Processing: Internal electronics interpret these resistance changes to determine the float position and corresponding liquid level.
Analog Signal Conversion: The calculated level is converted into a standard 4 to 20 mA signal representing the configured measurement range.
Continuous Level Monitoring: The signal can be transmitted to a compatible PLC, indicator, data acquisition system or industrial monitoring equipment.
This provides continuous measurement without direct contact between the float and sensing electronics.
C. Why Is the RDCLFS1000 Magnetoresistive Float Level Transmitter Used?
The RDCLFS1000 provides continuous level readings in industrial tanks, storage vessels and automated processes.
Key Benefits
Continuous Liquid Level Measurement: Monitors liquid level changes throughout the configured span, rather than only indicating high or low levels.
High Measurement Sensitivity: Magnetoresistive sensors detect changes in magnetic float position to support accurate measurement.
Standard Industrial Output: A 4 to 20 mA signal connects to compatible PLC analog inputs, controllers, process indicators and monitoring systems.
Wide Measuring Range: Options from 0.3 to 6 meters serve different tank sizes and industrial liquid storage requirements.
Stable Performance: The sensing design is intended to provide stable level readings and resistance to electromagnetic interference in industrial environments.
Multiple Material Options: Stainless steel 304, stainless steel 316, F4 and polypropylene offer choices for different liquids, subject to chemical compatibility.
Response to Level Changes: Float movement is detected electronically as the liquid level rises or falls.
Industrial Protection: The IP65 enclosure rating provides protection against dust ingress and water jets under specified conditions.
Low Power Consumption: Magnetoresistive sensing elements generally require relatively little electrical power.
Automation Compatibility: Continuous level data can support pump control, tank inventory monitoring and alarms through an external controller.
Common Applications
- Industrial water storage tanks and reservoirs
- Chemical processing and compatible chemical storage tanks
- Pharmaceutical liquid storage systems
- Water treatment plants
- Machinery and automotive coolant reservoirs
- Windshield washer fluid tanks
- Industrial process vessels and liquid distribution systems
- Automated tank level monitoring in manufacturing plants
Application Note: Chemical, high-temperature and pressurized services require verification of wetted materials, float buoyancy, medium density, process connections and operating limits.
D. Suitable Buyers
The RDCLFS1000 is suitable for OEMs, automation specialists, maintenance teams and industrial buyers requiring continuous liquid level measurement.
| Buyer Category | Typical Requirement |
|---|---|
| Industrial Plant Operators | Continuous level monitoring in storage tanks |
| Water Treatment Companies | Water storage and treatment level measurement |
| Chemical Manufacturers | Monitoring compatible chemical liquids |
| Pharmaceutical Industries | Liquid levels in process and storage vessels |
| OEM Equipment Manufacturers | Integrating transmitters into industrial machines |
| Automation System Integrators | Connecting 4 to 20 mA signals to PLCs |
| Automotive Equipment Manufacturers | Coolant and auxiliary fluid reservoir monitoring |
| Maintenance Engineers | Replacement of existing float level transmitters |
| Process Control Engineers | Continuous measurement and automation |
| Industrial Instrument Distributors | Supply of magnetoresistive level instruments |
| Machinery Manufacturers | Coolant tank and equipment reservoir monitoring |
| Industrial Project Contractors | Tank monitoring installations and projects |
Related product searches include magnetic float level sensor, 24V DC level transmitter and 4 to 20 mA float level sensor.
E. Frequently Asked Questions (FAQ)
1. What is the RDCL RDCLFS1000 Magnetoresistive Float Level Transmitter?
The RDCLFS1000 continuously measures liquid level by detecting a magnetic float position through magnetoresistive sensors. It converts this measurement into a 4 to 20 mA signal for monitoring and control.
2. How does the RDCLFS1000 Magnetoresistive Float Level Transmitter work?
A float containing a permanent magnet moves along the sensing probe as the liquid level changes. Magnetoresistive elements detect the changing magnetic field, and the transmitter's electronics calculate the float position and corresponding liquid level.
3. What is the measuring range of the RDCLFS1000?
The RDCLFS1000 supports a measuring range of 0.3 to 6 meters. Select the probe length and span to suit the tank.
4. What power supply is required for the RDCLFS1000?
The RDCLFS1000 operates on a 24V DC supply, making it suitable for compatible industrial instrumentation and control systems. Follow the selected unit's wiring requirements.
5. Does the RDCLFS1000 support a 4 to 20 mA output?
Yes. It provides a standard 4 to 20 mA analog output representing continuous liquid level measurements. It connects to compatible PLCs, indicators and monitoring systems.
6. Can the RDCLFS1000 be connected to a PLC?
Yes. The transmitter connects to a PLC with a compatible 4 to 20 mA analog input module. The PLC can display level and control pumps, alarms and other functions.
7. What is the accuracy of the RDCLFS1000?
The RDCLFS1000 is listed with 10 mm and 20 mm accuracy options. Confirm accuracy for the selected configuration.
8. What is the working temperature range of the RDCLFS1000?
The specified working temperature range is minus 20°C to 125°C. Confirm float and material compatibility with the liquid and temperature.
9. What is the maximum working pressure of the RDCLFS1000?
The listed working pressure is 1.0 MPa. The installed sensor, seals and process connection must all be rated for the actual tank pressure and operating conditions.
10. Can the RDCLFS1000 measure liquid levels in chemical storage tanks?
It can be considered for compatible chemical storage applications. Available material options include stainless steel 304, stainless steel 316, F4 and polypropylene. Chemical compatibility of the float, probe and seals must be checked before use.
11. How does a magnetoresistive float level transmitter differ from a conventional float level switch?
A magnetoresistive float transmitter continuously measures liquid level using magnetic field sensing. A conventional float level switch generally changes state when the float reaches a predetermined point. The RDCLFS1000 provides continuous measurement rather than only high-level or low-level detection.
12. Can the RDCLFS1000 be used for water tank level measurement?
Yes. It can continuously monitor water tank levels when the float density, construction materials and installation conditions are suitable. The signal may be connected to a compatible level indicator or PLC for remote monitoring and automation.
13. What is the protection rating of the RDCLFS1000?
The RDCLFS1000 has an IP65 protection rating, indicating protection against dust ingress and water jets under specified test conditions. The transmitter enclosure is not rated for continuous immersion based on IP65 alone.