Radical TechMart - The Marketplace for Process Industries
0
HTC Instruments HTC 8252IN Insulation Tester

HTC Instruments HTC 8252IN Insulation Tester

Non-returnable
₹82,600.00 ₹89,000.00
Add Note
Quantity
Buy Now
Product Details

Features:

  • Polarization Index (PI): Measures insulation resistance over time.
  • Dielectric Absorption (DAR): Tests dielectric properties of insulation.
  • Auto Power Off (APO): Auto shuts off after 15 minutes of inactivity.
  • USB Interface: Allows for easy data transfer and monitoring.
  • High Voltage Indication: Alerts the user if high voltage is detected.

Items Included:

  • Meter: 1 piece
  • High Voltage Bar: 1 piece (red)
  • High Voltage Test Lines: 2 pieces (black, green)
  • Monitoring Software CD: 1 piece
  • USB Communication Line: 1 piece
  • Charger: 1 piece
  • Manual and Certificate: 1 set
  • Instrument Box: 1 piece

Technical Specifications:

  • Model: HTC 8252
  • Rated Applied Voltage: 500V, 1000V, 2500V, 5KV, 10KV, 15KV
  • Resistance Limit Range: 0.01 MΩ ~ 50TΩ
  • Resolution: 0.01MΩ
  • Accuracy: ±3% reading ±5 digits
  • Output Short-Circuit Current: ≥6mA
  • Functions: Insulation resistance test, voltage test, current test, capacitance test
  • Basic Conditions: 23º±5ºC, below 75% relative humidity
  • Rated Voltage Accuracy: Rated voltage × (1±10%)

Measurement Ranges & Accuracy:

  • Insulation Resistance: 0.01MΩ to 50TΩ
    • Accuracy: ±3% reading ±5 digits
    • Resolution: 0.01MΩ
  • DC Voltage Range: 0.1V ~ 1000V
    • Accuracy: ±1.5% reading ±5 digits
    • Resolution: 0.1V
  • AC Voltage Range: 0.1V ~ 750V
    • Accuracy: ±1.5% reading ±5 digits
    • Resolution: 0.1V
  • DC Current Measurement: 0.01nA ~ 6mA
    • Accuracy: ±5% reading ±5 digits
    • Resolution: 0.01nA
  • Capacitance Test Range: 10nF ~ 60µF
    • Accuracy: ±10% reading ±5 digits
    • Resolution: 10nF

Additional Features:

  • Absorption Ratio & Polarization Index Measurement: Included
  • Insulation Resistance Between Measuring Line and Housing: ≥50MΩ
  • Pressure Resistance: AC 3kV/50Hz for 1 minute
  • Working Temperature & Humidity: -10ºC to +50ºC, <85% RH
  • Storage Temperature & Humidity: -10ºC to +55ºC, <90% RH
  • Instrument Weight: 2720g (including battery)

Power Consumption:

  • Standby: 30mA max (backlight off)
  • With Backlight On: 42mA max
  • During Measurement: 200mA max (backlight off)

Suitable for Safety Regulations:

  • Compliant with relevant safety standards and regulations for insulation testing.
Added to cart
Your cart has item(s).
- Can't add this product to the cart now. Please try again later.
Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.