The Autonics THD-D2-C Temperature and Humidity Transmitter is designed for simultaneous measurement of temperature and relative humidity in industrial and environmental monitoring applications. It measures temperature from minus 19.9°C to 60.0°C and humidity from 0.0 to 99.9 percent RH, providing separate 4 to 20 mA analog outputs for temperature and humidity. With a 24 VDC power supply, 200 mm sensor probe, 500 ms sampling cycle and IP65 protection except the sensor section, it is suitable for HVAC, BMS, cleanrooms, warehouses, production areas and industrial monitoring systems.
Customize
Share :
A. Product Overview
The Autonics THD-D2-C is a temperature and humidity transmitter designed to continuously measure both environmental parameters and convert them into standard industrial analog signals.
This model provides two separate 4 to 20 mA outputs, one representing temperature and the other representing relative humidity. These signals can be connected to compatible PLCs, controllers, indicators, data acquisition systems and building management systems.
The THD-D2-C is a non-display model, making it suitable for applications where measurements are monitored remotely through an automation or monitoring system rather than viewed directly on the transmitter.
Key Features
Brand: Autonics
Model: THD-D2-C
Series: THD
Product type: Temperature and humidity transmitter
Display: Non-display
Temperature measuring range: Minus 19.9°C to 60.0°C
Humidity measuring range: 0.0 to 99.9 percent RH
Temperature output: 4 to 20 mA
Humidity output: 4 to 20 mA
Power supply: 24 VDC
Sampling cycle: 500 ms
Sensor probe length: 200 mm
Temperature accuracy: Plus or minus 1.0°C at room temperature
Humidity accuracy: Typically plus or minus 2 percent RH from 10 to 90 percent RH at room temperature
Maximum humidity accuracy deviation: Plus or minus 2.5 percent RH
Resolution: 1 over 1000
Protection rating: IP65 except sensor section
Ambient operating temperature: Minus 20°C to 60°C
Suitable for continuous temperature and humidity monitoring
B. Working Principle
The Autonics THD-D2-C temperature and humidity transmitter contains sensing elements that continuously measure surrounding temperature and relative humidity.
The internal electronics process the measurements and convert them into two independent 4 to 20 mA analog signals.
One output represents temperature.
The second output represents relative humidity.
For example, as the measured temperature changes across the configured measurement range, the corresponding current output changes proportionally between 4 and 20 mA.
The same principle is used for humidity measurement.
These signals can then be sent to compatible equipment such as:
PLC
BMS
Process controller
Data logger
Remote indicator
Data acquisition system
Industrial monitoring system
The receiving system can display, record, trend or use the measurements for automatic control.
C. Why Is the Autonics THD-D2-C Used?
The Autonics THD-D2-C is used when both temperature and humidity need to be continuously monitored and transmitted to an industrial control or monitoring system.
1. Simultaneous Temperature and Humidity Measurement
A single transmitter measures both temperature and relative humidity.
2. Dual 4 to 20 mA Output
Separate analog outputs allow temperature and humidity to be monitored independently.
3. PLC Integration
The two 4 to 20 mA outputs can be connected to compatible PLC analog input channels.
4. Building Management Systems
Temperature and humidity measurements can be integrated into a BMS for centralized environmental monitoring.
5. HVAC Monitoring
The transmitter can help monitor environmental conditions in suitable HVAC and air handling applications.
6. Cleanroom Monitoring
Temperature and humidity are important environmental parameters in cleanrooms and controlled production areas.
7. Pharmaceutical Applications
It can be used in suitable pharmaceutical manufacturing, storage and environmental monitoring systems.
8. Warehouse Monitoring
The transmitter can continuously monitor storage areas where temperature and humidity conditions need to be controlled or recorded.
9. Data Logging
Its analog outputs can be connected to compatible data acquisition equipment for historical temperature and humidity recording.
10. Automated Environmental Control
A PLC or controller can use the transmitter signals to operate equipment such as ventilation systems, heaters, cooling systems, humidifiers or dehumidifiers.
D. Suitable Buyers
The Autonics THD-D2-C Temperature and Humidity Transmitter is suitable for:
HVAC contractors
Building management system integrators
Industrial automation companies
PLC system integrators
Control panel manufacturers
Pharmaceutical companies
Cleanroom solution providers
Warehouse operators
Food processing companies
Cold storage companies
Environmental monitoring companies
Laboratory equipment manufacturers
OEM machine builders
Data acquisition system integrators
Facility management companies
AHU manufacturers
Ventilation system manufacturers
Process automation companies
Factory maintenance departments
Industrial instrumentation companies
Electrical and instrumentation contractors
Production plants
It is particularly suitable for buyers searching for a 4 to 20 mA temperature and humidity transmitter, dual output humidity transmitter, 24 VDC humidity transmitter, HVAC humidity transmitter, BMS humidity transmitter or industrial temperature and humidity sensor.
FAQ
1. What is the Autonics THD-D2-C?
The Autonics THD-D2-C is a temperature and humidity transmitter that measures both temperature and relative humidity and provides separate analog outputs.
2. What is the temperature range of the THD-D2-C?
The temperature measurement range is minus 19.9°C to 60.0°C.
3. What is the humidity range?
The humidity measurement range is 0.0 to 99.9 percent RH.
4. What output does the THD-D2-C provide?
It provides separate 4 to 20 mA current outputs for temperature and humidity.
5. Does it provide separate outputs for temperature and humidity?
Yes. Temperature and humidity each have an independent 4 to 20 mA output.
6. What power supply does the THD-D2-C require?
The transmitter operates on 24 VDC.
7. Does the THD-D2-C have a display?
No. The THD-D2-C is a non-display model.
8. What is the temperature accuracy?
The temperature accuracy is plus or minus 1.0°C at room temperature.
9. What is the humidity accuracy?
Humidity accuracy is typically plus or minus 2 percent RH between 10 and 90 percent RH at room temperature, with a maximum deviation of plus or minus 2.5 percent RH.
10. What is the sampling cycle?
The sampling cycle is 500 ms.