


Methane (CH4) Gas Sensor and Transmitter 0 to 100% LEL | RDCL-CH4W
Customize
Share :
A. Product Overview
The RDCL-CH4W Wall Mount Methane Gas Sensor and Transmitter is an industrial instrument designed for continuous methane (CH4) concentration monitoring in ambient air. It measures methane from 0 to 100% LEL (Lower Explosive Limit), supporting combustible gas monitoring, environmental supervision and industrial automation.
Methane is a colorless, odorless and highly flammable gas commonly found in natural gas, biogas and industrial fuel systems. Monitoring methane concentrations helps identify potential gas accumulation.
The RDCL-CH4W features a protective wall mounted enclosure, signal compensation and multiple output options for integration with compatible PLC, SCADA and industrial monitoring systems.
Key Features
Methane (CH4) measurement range of 0 to 100% LEL
Measurement accuracy of ±5% full scale
Resolution of 1% LEL
Response time of 15 seconds or less
RS485, 4 to 20 mA, 0 to 5V and 0 to 10V output options
Operating power supply of 10 to 30V DC
Wall mounted protective enclosure
Internal signal compensation and calibration
Optional OLED display
Suitable for industrial monitoring and automation
Technical Specifications
Parameter | Specification |
|---|---|
Model | RDCL-CH4W |
Product Type | Wall Mount Methane Gas Sensor and Transmitter |
Gas Detected | Methane (CH4) |
Measurement Range | 0 to 100% LEL |
Accuracy | ±5% FS |
Resolution | 1% LEL |
Response Time | 15 seconds or less |
Repeatability | Within 2% |
Power Supply | 10 to 30V DC |
Power Consumption | 0.9W |
Output Options | RS485, 4 to 20 mA, 0 to 5V, 0 to 10V |
Operating Temperature | −20°C to 40°C |
Operating Humidity | 0 to 95% RH, non-condensing |
Pressure Range | 80 to 116 kPa |
Warm Up Time | Minimum 5 minutes |
Zero Drift | ±2% FS |
Reference Stability | Within 7% of signal value per year |
Reference Service Life | At least 24 months |
Installation | Wall Mount |
Display | Optional OLED |
Specifications are based on reference configurations. Confirm the exact output, sensing technology and hazardous area suitability before ordering.
B. Working Principle
The RDCL-CH4W detects methane concentration in surrounding air and converts the sensor response into an electrical output signal.
Step 1: Gas Detection
Methane enters the sensing area through the protective gas inlet. The sensing element responds to methane concentration. The exact detection technology depends on the supplied configuration.
Step 2: Signal Processing
The internal electronics process the sensor response using calibration and compensation functions to calculate methane concentration.
Step 3: Concentration Measurement
The measured methane concentration is expressed as a percentage of the Lower Explosive Limit (% LEL).
LEL represents the minimum concentration of a flammable gas in air capable of supporting flame propagation under specified conditions.
For methane, the commonly used LEL reference is approximately 5% by volume in air.
Sensor Reading | Approximate Methane Concentration |
|---|---|
0% LEL | 0% VOL |
10% LEL | 0.5% VOL |
20% LEL | 1.0% VOL |
50% LEL | 2.5% VOL |
100% LEL | 5.0% VOL |
Conversions are based on a methane LEL reference of 5% by volume.
Step 4: Output Transmission
The transmitter sends methane concentration measurements through the selected RS485 or analog output to compatible PLC, SCADA and monitoring systems.
Step 5: Continuous Monitoring
Connected monitoring equipment can display methane readings, record measurements and operate external alarms or ventilation controls according to configured thresholds.
C. Why Is the RDCL-CH4W Used?
The RDCL-CH4W is used for continuous methane monitoring in industrial and commercial environments where methane may be generated, stored, transported or released.
1. Natural Gas Leakage Monitoring
Monitors ambient methane concentration near natural gas pipelines, equipment and installations.
2. Biogas Plants
Supports methane monitoring around biogas production, processing and storage equipment.
3. Chemical Industries
Measures methane concentration in suitable chemical processing and gas handling environments.
4. Gas Storage Facilities
Helps monitor methane accumulation near gas storage and distribution equipment.
5. Industrial Workshops
Provides methane concentration measurements in facilities using natural gas equipment.
6. Parking Areas and Enclosed Facilities
Supports gas monitoring around compressed natural gas equipment and other potential methane sources.
7. Agricultural and Livestock Facilities
Monitors methane generated during organic waste decomposition and agricultural processes.
8. Wastewater Treatment Plants
Supports methane monitoring near anaerobic digesters and biogas handling installations.
9. Industrial Ventilation Monitoring
Provides methane concentration signals to compatible controllers for ventilation management.
10. PLC and SCADA Integration
Enables centralized methane measurement, data logging and industrial process supervision.
Safety Consideration: Applications involving explosion prevention or personnel protection require appropriately certified gas detection equipment and engineered alarm systems. Hazardous area certification must be verified separately.
D. Suitable Buyers
The RDCL-CH4W Wall Mount Methane Gas Sensor and Transmitter is suitable for industrial buyers requiring fixed methane concentration monitoring and automation integration.
Suitable Buyers | Typical Applications |
|---|---|
Natural Gas Distribution Companies | Methane monitoring near gas installations |
Biogas Plant Operators | Ambient methane monitoring |
Chemical Manufacturers | Methane measurement in process areas |
Industrial Gas Suppliers | Gas handling and storage monitoring |
Gas Storage Facilities | Fixed methane concentration monitoring |
Industrial Automation Companies | PLC and SCADA integration |
OEM Manufacturers | Integration into industrial equipment |
EPC Contractors | Industrial gas monitoring projects |
Wastewater Treatment Plants | Methane monitoring near digesters |
Industrial Safety Integrators | Engineered gas monitoring systems |
Manufacturing Industries | Monitoring natural gas equipment |
Environmental Monitoring Companies | Methane concentration measurement |
Agricultural and Livestock Facilities | Organic waste methane monitoring |
Research Laboratories | Experimental methane measurement |
Facility Management Companies | Monitoring applicable equipment rooms |
The RDCL-CH4W is particularly relevant for biogas plants, natural gas facilities, industrial automation companies and OEM manufacturers requiring RS485 or analog methane transmitters.
E. Frequently Asked Questions
1. What is the RDCL-CH4W Methane Gas Sensor?
The RDCL-CH4W is a wall mounted methane gas sensor and transmitter designed to measure methane concentration from 0 to 100% LEL in ambient air.
2. What is the measurement range?
The methane measurement range is 0 to 100% LEL, with a resolution of 1% LEL.
3. What does LEL mean?
LEL stands for Lower Explosive Limit. It represents the minimum gas concentration in air capable of supporting flame propagation under specified conditions.
4. What is the Lower Explosive Limit of methane?
The commonly used methane LEL reference is approximately 5% by volume in air. Using this reference, 50% LEL corresponds to approximately 2.5% methane by volume.
5. Does the RDCL-CH4W support RS485?
Yes. RS485 is available as an output option for integration with compatible industrial monitoring and automation systems.
6. Is a 4 to 20 mA output available?
Yes. The reference product family supports a 4 to 20 mA analog output for compatible PLC and monitoring equipment.
7. Can the methane sensor connect to a PLC?
Yes. Compatible configurations can connect to PLC systems using RS485 or analog output signals.
8. What is the accuracy?
The reference accuracy is ±5% full scale under specified operating conditions.
9. What is the response time?
The reference response time is 15 seconds or less.
10. What power supply is required?
The transmitter operates on a 10 to 30V DC power supply.
11. Can the RDCL-CH4W detect natural gas leakage?
It measures methane concentration and can support natural gas leakage monitoring. Safety critical leak detection requires separate verification of system suitability and certification.
12. Is the RDCL-CH4W suitable for biogas plants?
Yes. It supports ambient methane monitoring around compatible biogas production, processing and storage installations.


