Metrix+ CD 3 Non Contact Voltage Tester 12-1000V AC NCV Detector
The Metrix Plus CD 3 Non Contact Voltage Tester is a compact pen type electrical tester designed for quick detection of live AC voltage without direct electrical contact. It offers high sensitivity from 12V to 1000V AC and low sensitivity from 48V to 1000V AC, along with bar graph display, beep indication, flashlight and selectable sensitivity. With CAT III 1000V and CAT IV 600V safety compliance, it is suitable for electricians, maintenance technicians and electrical troubleshooting applications.
Customize
Share :
A. Product Overview
The Metrix Plus CD 3 is a non contact AC voltage detector designed to help users quickly identify the presence of live electrical voltage in wires, cables, outlets, circuit breakers and electrical circuits.
Its pen type construction makes it convenient for regular electrical maintenance and troubleshooting work.
Key Features
• Non contact AC voltage detection
• High sensitivity range: 12V to 1000V AC, 50 and 60 Hz
• Low sensitivity range: 48V to 1000V AC, 50 and 60 Hz
• Selectable high and low sensitivity
• Bar graph indication
• Audible beep indication
• Built in flashlight
• CAT III 1000V safety rating
• CAT IV 600V safety rating
• Operating temperature: 0°C to 40°C
• Storage temperature: minus 10°C to 50°C
• Operating humidity: up to 95 percent
• Operating altitude: up to 2000 m
• Power supply: 2 x 1.5V AAA batteries
B. Working Principle
The Metrix Plus CD 3 works using non contact voltage detection technology.
An energized AC conductor generates an alternating electric field around it. When the sensing tip of the CD 3 is brought near the conductor, its capacitive sensing circuit detects this electric field without requiring direct electrical contact with the conductor.
When AC voltage is detected, the instrument alerts the user through its bar graph and beep indication.
The selectable sensitivity allows the user to choose between:
High Sensitivity: 12V to 1000V AC
Low Sensitivity: 48V to 1000V AC
This can help technicians distinguish between different voltage detection requirements and reduce unwanted detection in certain applications.
C. Why Is the Metrix Plus CD 3 Used?
1. Live Wire Detection
The CD 3 allows electricians to quickly determine whether an AC wire or cable is energized.
2. Electrical Troubleshooting
Technicians can use it while investigating electrical faults to identify areas where AC voltage is present.
3. Checking Electrical Outlets
The tester can help determine whether voltage is present around suitable electrical outlets.
4. Cable Testing
It can be used to check cables for the presence of live AC voltage before maintenance work.
5. Circuit Breaker Inspection
Electricians can use the voltage tester during preliminary checks around circuit breakers and electrical distribution systems.
6. Electrical Panel Maintenance
The compact design makes it useful for technicians performing routine inspection and troubleshooting inside electrical installations.
7. Lighting Circuit Testing
The CD 3 can help identify the presence of AC voltage around lighting circuits and fixtures.
8. Quick Safety Checks
A non contact voltage tester provides a fast preliminary method of identifying energized conductors before beginning electrical work.
9. High and Low Sensitivity Testing
Selectable sensitivity gives technicians greater flexibility when working around different voltage levels and electrical environments.
D. Suitable Buyers
The Metrix Plus CD 3 Non Contact Voltage Tester is suitable for:
• Electricians
• Electrical engineers
• Electrical maintenance technicians
• Industrial maintenance teams
• Electrical contractors
• Facility maintenance personnel
• Control panel technicians
• Electrical panel manufacturers
• HVAC service technicians
• Automation technicians
• Machine maintenance engineers
• Manufacturing plants
• Building maintenance companies
• Electrical service companies
• Electrical installation contractors
• Maintenance contractors
• Engineering companies
• Electrical training institutes
• Industrial service technicians
Frequently Asked Questions
1. What is the Metrix Plus CD 3?
The Metrix Plus CD 3 is a pen type non contact AC voltage tester designed for quickly detecting the presence of live electrical voltage.
2. What is the voltage range of the CD 3?
The CD 3 offers two sensitivity ranges:
High sensitivity: 12V to 1000V AC
Low sensitivity: 48V to 1000V AC.
3. Is the CD 3 a non contact voltage tester?
Yes. It detects the electric field surrounding an energized AC conductor without requiring direct electrical contact.
4. What frequency does the CD 3 support?
The specified operating frequency is 50 and 60 Hz.
5. Does the CD 3 have adjustable sensitivity?
Yes. It provides selectable high sensitivity and low sensitivity modes.
6. How does the CD 3 indicate live voltage?
The instrument provides bar graph and beep indications when voltage is detected.
7. Does the Metrix Plus CD 3 have a flashlight?
Yes. A flashlight is included for use in poorly illuminated electrical areas.
8. Can the CD 3 measure the exact voltage value?
No. The CD 3 is designed primarily to detect the presence of AC voltage. It does not function like a digital multimeter that provides a precise numerical voltage measurement.
9. Can the CD 3 detect DC voltage?
The specified detection ranges are for AC voltage, so it should be used as an AC voltage detector.
10. What is the safety rating of the CD 3?
The CD 3 is specified for CAT III 1000V and CAT IV 600V.
11. Can electricians use the CD 3 for live wire testing?
Yes. Live wire detection is one of its primary applications.
12. Can it be used to check electrical sockets?
Yes. It can be used for preliminary detection of AC voltage around suitable electrical outlets.
13. Can it be used for circuit breaker testing?
It can help detect the presence of AC voltage around circuit breakers and electrical circuits during troubleshooting.
14. Can the CD 3 replace a multimeter?
No. The CD 3 is intended mainly for voltage presence detection. A digital multimeter is required when an exact numerical voltage measurement is needed.
15. What is the operating temperature of the CD 3?
The specified operating temperature is 0°C to 40°C.