Portable Ozone (O3) Gas Detector with Alarm | RDCL-O3P
The RDCL-O3P Portable Ozone (O3) Gas Detector is a handheld industrial ozone monitoring instrument designed for real-time measurement of ozone gas concentration in the surrounding air. Equipped with an electrochemical ozone sensor, digital LCD display, audible, visual and vibration alarms, rechargeable battery and data logging functionality, this portable ozone meter is suitable for ozone generators, water treatment plants, pharmaceutical industries, sterilization facilities, food processing units and industrial safety applications.
Customize
Share :
A. Product Overview
The RDCL-O3P Portable Ozone Gas Detector measures ozone (O3) concentrations in industrial and commercial environments. Ozone is used in sterilization, disinfection, water treatment and industrial processing, but excessive airborne concentrations can pose health risks.
Using an electrochemical sensor and natural diffusion sampling, the RDCL-O3P provides real-time ozone readings on a digital color display. Adjustable audible, visual and vibration alarms warn users when configured limits are reached. Its portable design supports workplace inspections, environmental monitoring and ozone safety assessments.
Key Features
- Real-time ozone (O3) detection using electrochemical sensing.
- Two range options: 0 to 10 ppm and 0 to 100 ppm.
- Resolution as fine as 0.01 ppm on the 0 to 10 ppm range.
- Adjustable high and low alarm thresholds.
- Audible, visual and vibration alarms.
- Digital color LCD for clear readings.
- Natural diffusion sampling without an external pump.
- Storage for up to 100,000 records with USB data export.
- Rechargeable lithium battery providing at least 8 hours of operation.
- Durable ABS housing with anti-slip rubber protection.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | RDCL-O3P |
| Product Type | Portable Ozone Gas Detector |
| Detectable Gas | Ozone (O3) |
| Sensor Technology | Electrochemical |
| Measurement Range | 0 to 10 ppm or 0 to 100 ppm |
| Resolution | 0.01 ppm or 0.1 ppm |
| Accuracy | ±6% Full Scale at specified test conditions |
| Repeatability | Within 2% |
| Response Time | Within 60 seconds |
| Detection Method | Natural Diffusion |
| Display | Digital Color Display |
| Alarms | Audible, Visual and Vibration |
| Data Storage | Up to 100,000 records |
| Battery | 3.7V, 3000 mAh Lithium Battery |
| Charging Interface | Micro USB Type B, 5V DC |
| Battery Operation | At least 8 hours |
| Operating Temperature | -10°C to 50°C |
| Operating Humidity | Below 95% RH, Non-Condensing |
B. Working Principle
The RDCL-O3P detects ambient ozone through an electrochemical reaction. Air enters the detector naturally, without a sampling pump, and ozone interacts with the sensing electrode to produce an electrical current proportional to its concentration.
1. Natural Diffusion: Ambient air enters through the instrument's gas inlet openings.
2. Electrochemical Detection: Ozone passes through a gas-permeable membrane and reacts at the sensing electrode.
3. Signal Generation: The electrochemical reaction produces a small electrical current corresponding to the ozone concentration.
4. Processing and Display: Electronics convert this signal into a digital reading displayed in parts per million (ppm).
5. Alarm Activation: When ozone reaches a configured alarm threshold, the detector provides audible, visual and vibration warnings.
6. Data Logging: Measurement records can be stored and exported to a computer through USB and compatible software for historical analysis.
C. Why Is a Portable Ozone Gas Detector Used?
A portable ozone meter helps detect elevated airborne ozone concentrations where ozone is generated, applied or released. It supports occupational safety checks, industrial inspections and monitoring before personnel enter ozone-treated areas. It measures ozone in air, not dissolved ozone in water.
Major Applications
1. Ozone Generator Monitoring: Checks ambient ozone levels near ozone generators, piping and associated equipment.
2. Water Treatment Plants: Monitors airborne ozone around water purification, oxidation and disinfection systems.
3. Pharmaceutical Industries: Supports ozone exposure monitoring in sterilization and controlled processing areas.
4. Food Processing Industries: Measures ozone around sanitation, packaging and food processing operations.
5. Sterilization and Disinfection Facilities: Assesses residual airborne ozone before personnel re-enter treated spaces.
6. Chemical and Petrochemical Industries: Supports workplace safety inspections where ozone is generated or used.
7. Environmental Monitoring: Provides localized ozone readings for air quality surveys and industrial assessments.
8. Research Laboratories: Measures ozone concentrations during laboratory experiments, testing and research.
9. Paper and Textile Industries: Helps monitor ozone used in oxidation, treatment and bleaching processes.
Benefits
- Measures ambient ozone concentrations in real time.
- Helps identify potentially unsafe ozone levels.
- Warns personnel through three alarm modes.
- Supports portable checks across multiple work areas.
- Assists ozone treatment, sterilization and maintenance monitoring.
- Records measurements for trend review and reporting.
D. Suitable Buyers
The RDCL-O3P Portable Ozone Gas Detector is suitable for organizations needing portable atmospheric ozone measurement.
| Suitable Buyers | Typical Requirements |
|---|---|
| Ozone Generator Manufacturers | Equipment testing and ambient ozone monitoring |
| Water Treatment Companies | Airborne ozone checks near treatment systems |
| Pharmaceutical Manufacturers | Sterilization area and ozone exposure monitoring |
| Food Processing Industries | Ozone monitoring during sanitation |
| Sterilization Service Providers | Residual airborne ozone checks after treatment |
| Industrial Safety Officers | Workplace ozone exposure monitoring |
| EHS and HSE Departments | Occupational gas safety inspections |
| Chemical Processing Plants | Industrial ozone monitoring |
| Environmental Testing Laboratories | Atmospheric ozone measurements |
| R&D Laboratories | Ozone measurement for experiments |
| Paper and Textile Industries | Ozone monitoring during industrial processes |
| Industrial Maintenance Contractors | Ozone equipment inspection and maintenance |
| Gas Detection Equipment Distributors | Portable ozone monitoring equipment supply |
Frequently Asked Questions (FAQs)
1. What is the RDCL-O3P Portable Ozone Gas Detector?
The RDCL-O3P is a portable instrument that measures ozone (O3) in ambient air using electrochemical sensing. It offers real-time readings, configurable alarms and data logging.
2. What is a portable ozone meter used for?
It measures airborne ozone during industrial safety checks, ozone generator inspections, sterilization activities, water treatment operations and environmental testing.
3. What measurement ranges are available?
The RDCL-O3P comes in 0 to 10 ppm and 0 to 100 ppm range options. Select the range according to the expected concentration and application.
4. How does the ozone detector work?
Ozone enters through natural diffusion and reacts within an electrochemical sensor. The resulting electrical signal is converted into a digital concentration reading.
5. Does it have an alarm system?
Yes. Configurable audible, visual and vibration alarms activate when measured ozone reaches the selected alarm thresholds.
6. Can it detect ozone gas leakage?
It can identify elevated ambient ozone that may be associated with leaks from equipment or distribution systems, but it does not pinpoint the exact leak location.
7. Can it be used in water treatment plants?
Yes, for airborne ozone monitoring around water treatment equipment. It does not directly measure dissolved ozone in water.
8. Is it suitable for pharmaceutical industries?
Yes. It supports atmospheric ozone checks in facilities using ozone for environmental treatment, sterilization or disinfection.
9. Does the RDCL-O3P support data logging?
Yes. It can store up to 100,000 measurement records, with data export through USB and compatible computer software.
10. What is the battery backup?
It uses a rechargeable 3.7V, 3000 mAh lithium battery and provides at least 8 hours of operation under specified conditions.
11. Can it measure ozone in indoor air?
Yes. It measures ozone in laboratories, industrial rooms, treatment spaces and enclosed processing facilities within its operating specifications.