Wall Mount Carbon Monoxide (CO) Gas Sensor and Transmitter | RDCL-COW
The RDCL-COW Wall Mount Carbon Monoxide (CO) Gas Sensor and Transmitter is an industrial gas monitoring instrument designed for continuous measurement of carbon monoxide concentration in ambient air. Featuring electrochemical sensing technology, it offers 0 to 1000 ppm and 0 to 2000 ppm measurement range options, 1 ppm resolution and a response time of 30 seconds or less. Available with RS485 Modbus RTU, 4 to 20 mA and voltage output options, the transmitter supports integration with PLC, SCADA, HVAC and ventilation control systems. Ideal for basement parking, underground garages, boiler rooms, industrial workshops, manufacturing facilities and environmental monitoring applications.
Customize
Share :
A. Product Overview
The RDCL-COW Wall Mount Carbon Monoxide Gas Sensor and Transmitter is designed for continuous carbon monoxide (CO) monitoring in industrial, commercial and enclosed environments. It uses electrochemical sensing technology to detect CO concentration and transmit measurements to compatible PLC, SCADA, BMS and ventilation control systems.
Carbon monoxide is a colorless, odorless and highly toxic gas produced by incomplete combustion of fuels such as petrol, diesel, natural gas, coal and wood. Continuous CO monitoring helps identify elevated gas concentrations and supports ventilation management.
The RDCL-COW is suitable for basement parking, underground garages, boiler rooms, generator rooms, industrial workshops and manufacturing facilities.
Key Features
Electrochemical carbon monoxide sensing technology
Measurement ranges of 0 to 1000 ppm and 0 to 2000 ppm
Measurement resolution of 1 ppm
Accuracy of ±5 ppm or ±10% under specified conditions
Response time of 30 seconds or less
RS485, 4 to 20 mA, 0 to 5V and 0 to 10V output options
Operating power supply of 10 to 30V DC
Wall mounted protective enclosure
Optional OLED display
Optional temperature and humidity monitoring in selected configurations
Compatible with suitable PLC, SCADA and BMS systems
Technical Specifications
Parameter | Specification |
|---|---|
Model | RDCL-COW |
Product Type | Wall Mount Carbon Monoxide Gas Sensor and Transmitter |
Gas Detected | Carbon Monoxide (CO) |
Sensing Technology | Electrochemical |
Measurement Range | 0 to 1000 ppm, 0 to 2000 ppm |
Accuracy | ±5 ppm or ±10% |
Resolution | 1 ppm |
Response Time | 30 seconds or less |
Repeatability | Within 2% |
Zero Drift | ±3 ppm |
Power Supply | 10 to 30V DC |
Power Consumption | 0.18W |
Output Options | RS485, 4 to 20 mA, 0 to 5V, 0 to 10V |
Operating Temperature | −20°C to 50°C |
Operating Humidity | 15% to 90% RH, non-condensing |
Pressure Range | 90 to 110 kPa |
Warm Up Time | Minimum 5 minutes |
Reference Stability | Within 2% of signal value per month |
Mounting | Wall Mount |
Display | Optional OLED |
Specifications represent reference configurations. Confirm the exact measurement range, output and optional features before ordering.
B. Working Principle
The RDCL-COW operates using the electrochemical gas sensing principle, converting carbon monoxide concentration into an electrical measurement signal.
Step 1: Gas Detection
Carbon monoxide from the surrounding atmosphere enters the sensor through a gas permeable membrane or protective opening.
Step 2: Electrochemical Reaction
CO molecules react at the sensing electrode, generating an electrical current related to the carbon monoxide concentration.
Step 3: Signal Processing
The transmitter processes the electrical signal using calibration and compensation functions to calculate the measured CO concentration.
Step 4: Concentration Measurement
The CO concentration is expressed in parts per million (ppm). For example, 50 ppm represents approximately 50 parts of carbon monoxide per million parts of the gas mixture.
Step 5: Output Transmission
The measured concentration is transmitted through the selected RS485 or analog output to compatible PLC, SCADA, BMS or monitoring equipment.
Step 6: Continuous Monitoring
Connected systems can display CO measurements, record data and operate ventilation fans or external alarms according to configured thresholds.
C. Why Is the RDCL-COW Used?
The RDCL-COW is used in locations where carbon monoxide may be generated through fuel combustion, engine exhaust or industrial processes.
1. Basement Parking Monitoring
Measures carbon monoxide concentration produced by vehicle exhaust in enclosed parking facilities.
2. Underground Parking Ventilation
Provides CO measurements to ventilation controllers for operating exhaust fans according to configured thresholds.
3. Boiler Room Monitoring
Monitors ambient CO concentration around suitable boilers and fuel burning equipment.
4. Industrial Workshop Monitoring
Supports continuous CO monitoring around engines, generators and combustion equipment.
5. Manufacturing Plants
Provides carbon monoxide concentration measurements for environmental monitoring and industrial process supervision.
6. Generator Rooms
Monitors CO concentration in rooms containing diesel or petrol generators.
7. HVAC and Building Management Systems
Enables integration with compatible HVAC controllers and BMS systems for CO based ventilation management.
8. Industrial Safety Monitoring
Supports environmental monitoring in workplaces where carbon monoxide exposure may occur.
9. Tunnels and Enclosed Facilities
Provides CO measurements for ventilation monitoring in vehicle tunnels and enclosed industrial areas.
10. PLC and SCADA Integration
Supports centralized CO monitoring, data recording and automated ventilation control through compatible industrial systems.
Safety Consideration: Applications requiring personnel protection, emergency alarms or regulatory compliance must use an appropriately certified and engineered gas detection system. The transmitter alone should not be considered a certified life safety alarm without verification.
D. Suitable Buyers
The RDCL-COW is suitable for industrial, commercial and institutional buyers requiring fixed carbon monoxide concentration monitoring.
Suitable Buyers | Typical Applications |
|---|---|
Basement Parking Operators | Continuous CO monitoring |
Commercial Building Developers | Parking ventilation systems |
HVAC Contractors | CO based ventilation control |
BMS Integrators | Building automation integration |
Industrial Automation Companies | PLC and SCADA monitoring |
Boiler Manufacturers | Boiler room CO monitoring |
Generator Installation Companies | Generator room monitoring |
Industrial Workshop Operators | Combustion emission monitoring |
Manufacturing Plants | Industrial CO concentration measurement |
Facility Management Companies | Commercial environmental monitoring |
EPC Contractors | Industrial gas monitoring projects |
OEM Manufacturers | CO sensor integration |
Environmental Monitoring Companies | Continuous CO measurement |
Industrial Safety Integrators | Engineered gas monitoring systems |
Tunnel Ventilation Contractors | Tunnel ventilation management |
The RDCL-COW is particularly suitable for HVAC contractors, basement parking ventilation contractors, BMS integrators, industrial automation companies and OEM manufacturers requiring a wall mounted CO transmitter with industrial output signals.
E. Frequently Asked Questions
1. What is the RDCL-COW Carbon Monoxide Gas Sensor?
The RDCL-COW is a wall mounted electrochemical carbon monoxide gas sensor and transmitter designed for continuous CO concentration measurement in ambient air.
2. What is the working principle of the RDCL-COW?
It uses electrochemical sensing technology. CO molecules react at the sensing electrode, generating an electrical signal proportional to the measured concentration.
3. What measurement ranges are available?
The reference configurations offer 0 to 1000 ppm and 0 to 2000 ppm measurement ranges.
4. What is the accuracy of the CO transmitter?
The reference measurement accuracy is ±5 ppm or ±10% under specified operating conditions.
5. Does the RDCL-COW support RS485 Modbus RTU?
RS485 is available as an output option. Compatible configurations support Modbus RTU communication with industrial monitoring systems.
6. Is a 4 to 20 mA output available?
Yes. The RDCL-COW offers a 4 to 20 mA analog output option for compatible PLC and industrial monitoring equipment.
7. Can the RDCL-COW connect to a PLC?
Yes. The transmitter can connect to a compatible PLC using RS485 or the appropriate analog output interface.
8. Can this CO sensor control parking ventilation fans?
The transmitter sends CO concentration measurements to external controllers, which can operate ventilation fans based on programmed thresholds.
9. Why is carbon monoxide monitoring important in basement parking?
Vehicle exhaust can produce carbon monoxide. Continuous monitoring helps detect elevated CO concentrations and supports ventilation management.
10. Is the RDCL-COW suitable for underground garages?
Yes. It is designed for fixed carbon monoxide concentration monitoring in underground parking areas and similar enclosed facilities.
11. What is the response time of the RDCL-COW?
The reference response time is 30 seconds or less under specified conditions.
12. What is the measurement resolution?
The RDCL-COW has a reference carbon monoxide measurement resolution of 1 ppm.