The RDCL-H2SW Wall Mount Hydrogen Sulfide (H2S) Gas Sensor and Transmitter is an industrial electrochemical gas sensor designed for continuous monitoring of hydrogen sulfide concentration. Featuring a measurement range of 0 to 100 ppm, IP65 protection and selectable RS485, 4 to 20mA, 0 to 5V and 0 to 10V outputs, it provides reliable gas concentration measurement for industrial applications. With an optional OLED display and optional temperature and humidity measurement, the sensor is suitable for chemical plants, wastewater treatment facilities, industrial workshops, livestock farms, parking garages and environmental monitoring systems.
Customize
Share :
A. Product Overview
The RDCL-H2SW Wall Mount Hydrogen Sulfide (H2S) Gas Sensor and Transmitter is designed for continuous hydrogen sulfide monitoring in industrial environments. H2S is a toxic, flammable gas commonly found in wastewater treatment, sewage systems, chemical plants, petroleum industries and organic waste decomposition.
Using electrochemical sensing technology, the RDCL-H2SW measures H2S concentrations from 0 to 100 ppm with 1 ppm resolution. It supports RS485, 4 to 20 mA, 0 to 5V and 0 to 10V outputs for integration with compatible PLC, SCADA and industrial monitoring systems.
Its IP65 rated enclosure provides protection against dust and water jets. Optional OLED display and temperature and humidity monitoring configurations are also available.
Key Features
Electrochemical hydrogen sulfide sensing
Measurement range: 0 to 100 ppm
Accuracy: ±2 ppm or ±10%
Resolution: 1 ppm
Response time: ≤35 seconds
Repeatability: ≤2%
RS485 and analog output options
Power supply: 10 to 30V DC
IP65 protective enclosure
Optional OLED display
Optional temperature and humidity measurement
Wall mounted installation
Technical Specifications
Parameter | Specification |
|---|---|
Model | RDCL-H2SW |
Product Type | Hydrogen Sulfide Gas Sensor and Transmitter |
Gas Detected | Hydrogen Sulfide (H2S) |
Sensing Technology | Electrochemical |
Measurement Range | 0 to 100 ppm |
Accuracy | ±2 ppm or ±10% |
Resolution | 1 ppm |
Response Time | ≤35 seconds |
Repeatability | ≤2% |
Stability | ≤2% of signal value per month |
Zero Drift | ±5 ppm from −20°C to 40°C |
Outputs | RS485, 4 to 20 mA, 0 to 5V, 0 to 10V |
Power Supply | 10 to 30V DC |
Operating Temperature | −20°C to 50°C |
Operating Humidity | 15% to 90% RH, non-condensing |
Operating Pressure | 90 to 110 kPa |
Protection Rating | IP65 |
Warm Up Time | At least 5 minutes |
Sensor Service Life | At least 24 months under specified conditions |
Installation | Wall Mount |
Display | Optional OLED |
Additional Measurement | Optional temperature and humidity |
B. Working Principle
The RDCL-H2SW uses electrochemical sensing technology to detect hydrogen sulfide and convert its concentration into an electrical output signal.
1. Gas Detection: H2S enters the sensing element through a gas permeable interface.
2. Electrochemical Reaction: Hydrogen sulfide reacts at the sensing electrode, producing an electrical current related to its concentration.
3. Signal Processing: Internal electronics process the signal and calculate H2S concentration in parts per million (ppm).
4. Output Transmission: Measurements are transmitted through RS485 or the selected analog output to compatible PLC, SCADA and monitoring systems.
5. Continuous Monitoring: Connected systems can display gas concentrations, record measurements and activate external alarms when appropriately configured.
C. Why Is the RDCL-H2SW Used?
The RDCL-H2SW monitors hydrogen sulfide in industrial environments where H2S may be generated, released or accumulated. Continuous monitoring helps identify abnormal gas concentrations and supports workplace safety and environmental management.
1. Gas Leakage Monitoring: Detects elevated H2S concentrations around chemical processing, wastewater handling and industrial equipment.
2. Wastewater Treatment: Monitors hydrogen sulfide generated during organic matter decomposition in wastewater treatment plants and pumping stations.
3. Sewage Treatment Plants: Supports continuous H2S monitoring around sewage processing and handling facilities.
4. Workplace Safety: Provides concentration data for industrial exposure assessment and safety procedures.
5. Chemical and Petrochemical Industries: Measures H2S in suitable chemical processing and petroleum facilities.
6. Livestock Farms: Monitors hydrogen sulfide released from decomposing manure and agricultural waste.
7. Industrial Ventilation: Provides H2S concentration measurements to compatible ventilation controllers.
8. Environmental Monitoring: Supports monitoring of hydrogen sulfide emissions in industrial and agricultural environments.
9. PLC and SCADA Integration: Enables centralized monitoring, data logging and process supervision.
Industrial Applications
Wastewater and sewage treatment plants
Sewage pumping stations
Chemical and petrochemical industries
Petroleum processing facilities
Livestock farms and manure handling
Industrial wastewater processing
Environmental gas monitoring
Industrial ventilation systems
PLC and SCADA monitoring installations
Safety Note: Applications requiring personnel protection or installation in hazardous areas must use appropriately certified equipment and engineered gas detection systems.
D. Suitable Buyers
Suitable Buyers | Applications |
|---|---|
Sewage Treatment Plant Operators | H2S monitoring in treatment facilities |
Wastewater Treatment Companies | Gas monitoring in wastewater processing |
Chemical Manufacturers | Process area H2S monitoring |
Petrochemical Industries | Hydrogen sulfide concentration monitoring |
Automation System Integrators | PLC and SCADA integration |
EHS and Industrial Safety Teams | Workplace gas monitoring |
Livestock Farm Operators | Manure related H2S monitoring |
OEM Manufacturers | Gas monitoring equipment integration |
EPC Contractors | Industrial gas monitoring projects |
Instrumentation Engineers | Fixed H2S monitoring installations |
E. Frequently Asked Questions
1. What is the RDCL-H2SW Hydrogen Sulfide Gas Sensor?
The RDCL-H2SW is a wall mounted electrochemical gas sensor and transmitter designed for continuous H2S concentration monitoring.
2. What is its measurement range?
The standard measurement range is 0 to 100 ppm with 1 ppm resolution.
3. How does the H2S sensor work?
It uses electrochemical sensing technology. Hydrogen sulfide reacts at the sensing electrode, generating an electrical signal that is processed into a ppm reading.
4. What output signals are available?
RS485, 4 to 20 mA, 0 to 5V and 0 to 10V output options are available.
5. Can it connect to PLC or SCADA systems?
Yes. Compatible PLC and SCADA systems can receive measurements through the selected RS485 or analog output.
6. What power supply is required?
The transmitter operates on a 10 to 30V DC power supply.
7. Is the RDCL-H2SW waterproof?
It features an IP65 enclosure that protects against dust and water jets but is not designed for submersion.
8. Can the sensor be installed outdoors?
Outdoor installation may be possible within specified environmental limits. Weather exposure and condensation protection should be considered.
9. Does it have an OLED display?
An optional OLED display is available for local H2S concentration readings.
10. Can it measure temperature and humidity?
Yes. Optional temperature and humidity measurement is available in selected configurations.
11. What is the response time?
The reference response time is 35 seconds or less.
12. What is the measurement accuracy?
The reference accuracy is ±2 ppm or ±10%, depending on measurement conditions and configuration.