Wall Mount Oxygen (O2) Gas Sensor and Transmitter | RDCL-O2W
The RDCL-O2W Wall Mount Oxygen (O2) Gas Sensor and Transmitter is designed for accurate and continuous monitoring of oxygen concentration in industrial and commercial environments. Equipped with electrochemical sensing technology, it provides reliable oxygen measurement with a fast response time and stable performance. Available with RS485 Modbus RTU, 4 to 20 mA and voltage output options, it supports integration with PLC, SCADA and industrial monitoring systems. Ideal for warehouses, chemical plants, pharmaceutical facilities, industrial workshops, ventilation systems and environmental monitoring applications.
Customize
Share :
A. Product Overview
The RDCL-O2W Wall Mount Oxygen Gas Sensor and Transmitter measures oxygen (O2) concentration in ambient air for fixed industrial monitoring, workplace safety and process automation. Normal air contains approximately 20.9% oxygen by volume. Oxygen deficiency or enrichment can create hazardous conditions, making continuous measurement important in areas where gas concentrations may change.
The RDCL-O2W uses electrochemical sensing technology and transmits measurements to compatible PLC, SCADA, BMS or data acquisition systems. Its wall-mounted enclosure and gas-permeable sensing membrane are designed for fixed installation. Depending on the selected configuration, outputs include RS485 Modbus RTU, 4 to 20 mA, 0 to 5 V and 0 to 10 V.
Key Features
- Electrochemical oxygen sensing for continuous ambient monitoring.
- Wall-mounted construction for industrial installations.
- Measurement ranges: 0 to 30% VOL (RS485) or 0 to 25% VOL (analog versions).
- Reference accuracy: ±2% full scale; resolution: 0.1% VOL.
- Response time: 10 seconds or less under specified conditions.
- Output choices: RS485 Modbus RTU, 4 to 20 mA, 0 to 5 V and 0 to 10 V.
- 10 to 30 V DC supply and reference repeatability within 1%.
- Optional OLED display in selected configurations.
- Optional combined oxygen, temperature and humidity monitoring in compatible versions.
- Integration with suitable industrial monitoring and automation equipment.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | RDCL-O2W |
| Product type | Wall Mount Oxygen Gas Sensor and Transmitter |
| Detected gas | Oxygen (O2) |
| Sensor technology | Electrochemical |
| Mounting | Wall mounted |
| RS485 measurement range | 0 to 30% VOL |
| Analog measurement range | 0 to 25% VOL |
| Accuracy | ±2% FS |
| Resolution | 0.1% VOL |
| Output options | RS485, 4 to 20 mA, 0 to 5 V, 0 to 10 V |
| Supply | 10 to 30 V DC |
| Response time | 10 seconds or less |
| Warm-up time | Minimum 5 minutes |
| Operating temperature | −20°C to 50°C |
| Operating humidity | 5% to 95% RH, non-condensing |
| Pressure range | 90 to 110 kPa |
| Repeatability | Within 1% |
| Display | Optional OLED |
Note: These are reference wall-mounted sensor specifications. Confirm the exact RDCL-O2W range, outputs and options against the final product datasheet before ordering.
B. Working Principle
The RDCL-O2W measures oxygen concentration through an electrochemical reaction and converts the sensor response into a signal suitable for monitoring equipment.
1. Oxygen diffusion: Ambient oxygen passes through a gas-permeable membrane into the sensing chamber, while the membrane helps limit contaminants.
2. Electrochemical reaction: Oxygen reacts within a sensor containing electrodes and electrolyte, producing a small electrical current.
3. Signal generation: The current varies with oxygen concentration in the surrounding air.
4. Signal processing: The transmitter amplifies and processes the signal using calibration and compensation to calculate the oxygen level.
5. Measurement: Oxygen is expressed as percentage by volume (% VOL). Typical atmospheric oxygen is approximately 20.9% VOL.
6. Output transmission: The configured RS485 Modbus RTU, current or voltage output sends the measurement to compatible PLCs, SCADA systems or controllers.
7. Continuous monitoring: Connected systems can display readings, log trends and trigger configured control or alarm functions when appropriate equipment is provided.
C. Applications and Uses
The RDCL-O2W oxygen transmitter provides continuous oxygen measurement wherever displacement by other gases, consumption of oxygen or oxygen enrichment could affect industrial conditions.
Major Applications
1. Industrial oxygen monitoring: Observe oxygen concentrations in process and equipment areas where atmospheric conditions can change.
2. Oxygen deficiency monitoring: Detect declining oxygen levels where nitrogen, carbon dioxide or other gases may displace air.
3. Oxygen enrichment monitoring: Track elevated oxygen concentrations within the instrument's range in locations where increased fire risk is a concern.
4. Chemical processing plants: Monitor ambient oxygen near applicable chemical manufacturing and process installations.
5. Pharmaceutical facilities: Observe oxygen conditions around nitrogen-purging and controlled-atmosphere equipment.
6. Warehouses and storage facilities: Provide fixed oxygen readings in suitable industrial gas storage or controlled-atmosphere areas.
7. Workshops and manufacturing units: Measure oxygen levels in areas with potential gas displacement or enrichment.
8. Underground utility areas: Support engineered monitoring systems for tunnels or poorly ventilated locations when properly assessed and installed.
9. HVAC and ventilation systems: Provide oxygen concentration data for selected ventilation supervision applications.
10. PLC and SCADA integration: Supply measurements for centralized monitoring, recording and process supervision.
Benefits
- Continuous readings from a fixed monitoring point.
- Early identification of oxygen deficiency or enrichment trends.
- Signal outputs for automated monitoring and data logging.
- Less dependence on occasional manual measurements at the monitored point.
- Suitable for integration into wider industrial monitoring systems.
Safety note: A fixed oxygen transmitter alone does not satisfy personnel safety or confined-space entry requirements. Such applications require suitable certified detection equipment, alarms, calibration, risk assessment and relevant safety procedures.
D. Suitable Buyers
| Suitable Buyers | Typical Requirements |
|---|---|
| Chemical manufacturers | Oxygen monitoring in process areas |
| Pharmaceutical industries | Monitoring near nitrogen-purging systems |
| Industrial automation companies | PLC and SCADA integration |
| OEM manufacturers | Oxygen measurement within equipment |
| Gas monitoring system integrators | Fixed oxygen measurement systems |
| Industrial safety suppliers | Components for engineered gas safety systems |
| Warehouses and storage operators | Oxygen monitoring in controlled areas |
| HVAC contractors | Selected ventilation monitoring applications |
| Environmental monitoring companies | Ambient oxygen measurement and recording |
| Research laboratories | Oxygen monitoring in laboratory environments |
| Industrial gas suppliers | Monitoring near gas installations |
| Manufacturing plants | Workplace oxygen concentration monitoring |
| Facility management companies | Fixed monitoring of industrial premises |
| EPC contractors | Integration into industrial monitoring projects |
This model is particularly relevant to buyers requiring a wall mount oxygen sensor with RS485 or analog output for compatible industrial monitoring systems.
E. Frequently Asked Questions (FAQs)
1. What is the RDCL-O2W Oxygen Gas Sensor?
The RDCL-O2W is a wall-mounted electrochemical oxygen sensor and transmitter for continuous ambient oxygen measurement. It sends readings through the selected industrial output interface.
2. How does the RDCL-O2W oxygen sensor work?
Oxygen diffuses into an electrochemical sensing element and generates a current related to oxygen concentration. Transmitter electronics convert this signal into a measured oxygen percentage.
3. What is its measurement range?
Reference RS485 versions measure 0 to 30% VOL; reference analog versions measure 0 to 25% VOL. Confirm the range for the selected configuration.
4. What is the normal oxygen concentration in air?
Normal atmospheric air contains approximately 20.9% oxygen by volume. The value can vary with environmental conditions and other gases.
5. Does it support RS485 Modbus RTU?
Yes, RS485 Modbus RTU is an available reference option for transmitting oxygen data to compatible PLC, SCADA and monitoring systems.
6. Is a 4 to 20 mA output available?
Yes. A 4 to 20 mA analog output option is available for suitable industrial controllers and PLC analog input modules.
7. Can the RDCL-O2W connect to a PLC?
Yes, with a compatible RS485 or analog output configuration. Confirm power, electrical compatibility and communication settings before installation.
8. What is the oxygen transmitter's accuracy?
Reference accuracy is ±2% full scale under specified conditions. Actual performance depends on calibration, operating environment and configuration.
9. What is its response time?
The reference sensor response time is 10 seconds or less under specified test conditions.
10. Where can the wall mount oxygen sensor be installed?
Possible locations include industrial workshops, warehouses, chemical plants, pharmaceutical facilities and equipment rooms. Select installation points based on ventilation, potential gas hazards, environmental limits and manufacturer instructions.