


Wall Mount TVOC Air Quality Sensor and Transmitter | RDCL-TVOCW
The RDCL-TVOCW Wall Mount TVOC Air Quality Sensor and Transmitter is an industrial air quality monitoring instrument designed for continuous measurement of Total Volatile Organic Compounds (TVOC) in indoor and industrial environments. Featuring a measurement range of 0 to 60000 ppb, 1 ppb resolution, 1 second data refresh time and selectable RS485, 4 to 20mA, 0 to 5V and 0 to 10V outputs, it provides real time TVOC concentration monitoring. With a wall mounted protective enclosure and 10 to 30V DC power supply, it is suitable for HVAC systems, smart buildings, chemical plants, laboratories, pharmaceutical facilities and environmental monitoring applications.
Customize
Share :
A. Product Overview
The RDCL-TVOCW Wall Mount TVOC Air Quality Sensor and Transmitter is designed for continuous Total Volatile Organic Compounds (TVOC) monitoring in indoor, commercial and industrial environments.
VOCs are released from paints, solvents, adhesives, furniture, cleaning products and manufacturing processes. Elevated TVOC levels may indicate poor indoor air quality.
The RDCL-TVOCW measures 0 to 60000 ppb with 1 ppb resolution and a 1 second data refresh interval. RS485 and analog output options enable integration with compatible PLC, SCADA, BMS and industrial monitoring systems.
Key Features
Continuous TVOC concentration monitoring
Measurement range: 0 to 60000 ppb (0 to 60 ppm)
Resolution: 1 ppb
Accuracy: ±8% full scale under reference conditions
Data refresh interval: 1 second
Outputs: RS485, 4 to 20 mA, 0 to 5V and 0 to 10V
Power supply: 10 to 30V DC
Protective wall mounted enclosure
Suitable for HVAC, BMS and industrial automation
Technical Specifications
Parameter | Specification |
|---|---|
Model | RDCL-TVOCW |
Product Type | Wall Mount TVOC Sensor and Transmitter |
Measurement | Total Volatile Organic Compounds |
Range | 0 to 60000 ppb (0 to 60 ppm) |
Resolution | 1 ppb |
Accuracy | ±8% FS |
Reference Conditions | Ethanol at 0.5 ppm, 25°C and 50% RH |
Data Refresh | 1 second |
Output Options | RS485, 4 to 20 mA, 0 to 5V, 0 to 10V |
Power Supply | 10 to 30V DC |
Operating Temperature | −40°C to 80°C |
Operating Humidity | 0 to 95% RH, non-condensing |
Preheating Time | Up to 24 hours |
Installation | Wall Mount |
Enclosure | Protective Industrial Housing |
Specifications are based on the reference configuration. Confirm final product specifications before ordering.
B. Working Principle
The RDCL-TVOCW uses a gas sensitive sensing element whose electrical conductivity changes when exposed to volatile organic compounds.
1. Air Exposure: Air containing VOCs from solvents, paints, adhesives or other sources reaches the sensing element.
2. Gas Sensing: VOCs interact with the sensing element, changing its electrical conductivity according to the concentration and composition of the gas mixture.
3. Signal Processing: Internal electronics convert the sensor response into a TVOC concentration reading expressed in parts per billion (ppb).
4. Measurement Update: The transmitter refreshes measurement data every 1 second.
5. Output Transmission: TVOC measurements are transmitted through RS485 or the selected analog output to compatible PLC, SCADA and BMS systems.
6. Centralized Monitoring: Connected equipment can record measurements, display TVOC levels and generate configured concentration alerts.
Note: TVOC sensors provide an aggregate indication of volatile organic compounds rather than identifying individual gases separately.
C. Why Is the RDCL-TVOCW Used?
The RDCL-TVOCW helps monitor volatile organic compound concentrations and supports indoor air quality assessment, ventilation management and industrial environmental monitoring.
1. Indoor Air Quality: Monitors VOC emissions from furniture, paints, cleaning products and building materials.
2. HVAC and Ventilation: Provides TVOC concentration data to compatible ventilation control systems.
3. Smart Buildings: Enables centralized air quality monitoring through compatible building management systems.
4. Chemical Manufacturing: Monitors VOC concentration changes in suitable chemical processing and storage areas.
5. Paint and Coating Industries: Supports monitoring of volatile compounds released from solvents, varnishes and coatings.
6. Laboratories: Measures general TVOC levels in laboratory environments using organic solvents.
7. Pharmaceutical Industries: Supports air quality monitoring in selected manufacturing areas handling volatile chemicals.
8. Industrial Automation: Integrates with PLC, SCADA and data acquisition systems for centralized monitoring.
Industrial Applications
Indoor air quality monitoring
HVAC and ventilation systems
Smart buildings and commercial offices
Chemical manufacturing plants
Paint and coating industries
Pharmaceutical facilities
Laboratories and research centers
Furniture and wood processing
Industrial environmental monitoring
PLC, SCADA and BMS installations
D. Suitable Buyers
Suitable Buyers | Applications |
|---|---|
HVAC Contractors | Indoor air and ventilation monitoring |
BMS Integrators | Centralized TVOC monitoring |
Chemical Manufacturers | Industrial VOC monitoring |
Pharmaceutical Companies | Solvent related air quality monitoring |
Paint and Coating Manufacturers | VOC monitoring in production areas |
Environmental Monitoring Companies | Indoor and industrial air assessment |
Research Laboratories | General VOC concentration monitoring |
Automation Integrators | PLC and SCADA integration |
OEM Manufacturers | Air quality monitoring equipment |
Facility Managers and EHS Teams | Workplace environmental monitoring |
E. Frequently Asked Questions
1. What is the RDCL-TVOCW TVOC Sensor?
The RDCL-TVOCW is a wall mounted industrial sensor and transmitter designed for continuous Total Volatile Organic Compounds monitoring.
2. What does TVOC mean?
TVOC stands for Total Volatile Organic Compounds, representing an aggregate measurement of volatile organic compounds present in air.
3. What is the measurement range?
The reference range is 0 to 60000 ppb, equivalent to 0 to 60 ppm.
4. What is the resolution?
The RDCL-TVOCW offers 1 ppb measurement resolution.
5. How does the TVOC sensor work?
It detects changes in the electrical conductivity of a gas sensitive element exposed to VOCs and converts the response into a TVOC reading.
6. What output signals are available?
RS485, 4 to 20 mA, 0 to 5V and 0 to 10V, depending on configuration.
7. Can it connect to PLC or SCADA systems?
Yes. Compatible PLC and SCADA systems can receive measurements through the selected analog or digital output.
8. What power supply is required?
The transmitter operates on 10 to 30V DC.
9. Is it suitable for HVAC applications?
Yes. It supports TVOC monitoring in compatible HVAC and ventilation systems.
10. Can it be used in smart buildings?
Yes. It can integrate with compatible BMS and indoor air quality monitoring equipment.
11. What is the data refresh interval?
The reference data refresh interval is 1 second.
12. What is the accuracy?
The reference accuracy is ±8% full scale under specified ethanol test conditions at 25°C and 50% RH. Actual response depends on the VOC mixture.


